Topcon GPT-2000 用户手册

下载
页码 168
   9 MEMORY MANAGER MODE
9-5
9.2.2 Coordinate Data Searching
Example searching :Point number searching 
Operating procedure
Operation
Display
1
Press the [F3](MEMORY MGR.) key from the
menu 1/3.
[F3]
2
Press the [F2](SEARCH) key.
[F2]
3
Press the [F2](COORD. DATA) key.
[F2]
4
Press the [F1](INPUT) key and enter File Name. 
Press the [F4](ENT) key. *1)
[F1]
Enter FN
[F4]
5
Press the [F3](PT# DATA) key.
[F3]
6
Press the [F1](INPUT) key and enter PT#.
Press the [F4](ENT) key. *1)
[F1]
Enter PT#
[F4]
"
 " represents data shown on the display is the stored data. 
Press the [
] or [
] key to scroll to next or previous point.
To search COORD. DATA of the same point number, press the [
]or[
] key.
  
MEMORY MGR.      1/3
 F1:FILE STATUS
 F2:SEARCH
 F3:FILE MAINTAN  P
  
SEARCH
 F1:MEAS. DATA
 F2:COORD. DATA
 F3:PCODE LIB.
  
SELECT A FILE
 FN:_________ 
 
INPUT LIST ––– ENTER
  
COORD. DATA SEARCH
 F1:FIRST DATA   
 F2:LAST DATA
 F3:PT# DATA
PT# DATA SEARCH
 PT#:_________ 
 
INPUT –––  ––– ENTER
  
PT#
TOP-104 
 N 
  100.234 m
 E 
   12.345 m
 Z 
    1.678 m