   4 DISTANCE MEASUREMENT
4.7.4 Column Offset Measurement
If it is possible to measure circumscription point (P1) of column directly, the distance to the center of the 
column (P0), coordinate and direction angle can be calculated by measured circumscription points (P2) 
and (P3).
The direction angle of  the center of the column is 1/2 of total direction angle of circumscription points 
(P2) and (P3).
When setting the coordinate value for the occupied station, refer to Section 5.1 “Setting Coordinate 
Values of Occupied Point”.
Example: Non-prism measurement
Operating procedure
Operation
Display
1
Press the [F4](P1
) key from distance measuring 
mode to get the function on page 2.
[F4]
2
Press the [F1](OFSET)  key.
[F1]
3
Press the [F4](P
) key.
[F4]
4
Press the [F1](COLUMN OFFSET)  key.
[F1]
5
Press the [F3](NP/P) key to change to the non-
prism mode.
[F3]
 
P
P
P
2
3
P
HR:  120°30'40" 
HD:     123.456 m
VD:       5.678 m
MEAS  MODE  NP/P P1
OFSET S.O   S/A  P2
OFFSET           1/2
 F1:ANG.OFFSET
 F2:DIST.OFFSET
 F3:PLANE OFFSET  P
OFFSET           2/2
 F1:COLUMN OFFSET
 
                  P
COLUMN OFFSET
 Center           
 HD:           m
MEAS  ---  NP/P ---
COLUMN OFFSET
 Center           
N
P
 HD:           m
MEAS  ---  NP/P ---