4 - 1
4-1 PREPARATION
Some adjustments must be performed on the “ADJUSTMENT MODE”. CS-FR3000 
CLONING SOFTWARE
, OPC-478 CLONING
CABLE
and OPC-592 
ADAPTOR CABLE
are required when entering the adjustment mode. Refer to the next page in detail.
■ REQUIRED TEST EQUIPMENT
SECTION 4 ADJUSTMENT PROCEDURES
EQUIPMENT
DC power supply
RF power meter
(terminated type)
Frequency counter
FM deviation meter
GRADE AND RANGE
Output voltage
: 13.6 V DC [FR3000]
13.2 V DC [FR3100]
Current capacity
: 25 A or more
Measuring range
: 1–100 W
Frequency range
: 100–300 MHz
Impedance
: 50 
Ω
SWR
: Less than 1.2 : 1
Frequency range
: 0.1–600 MHz
Frequency accuracy : ±1 ppm or better
Sensitivity
: 100 mV or better
Frequency range
: DC–600 MHz
Measuring range
: 0 to ±5 kHz
EQUIPMENT
Audio generator
Attenuator
Standard signal 
generator (SSG)
AC millivoltmeter
Oscilloscope
Digital multimeter
GRADE AND RANGE
Frequency range
: 300–3000 Hz
Output level
: 1–500 mV
Power attenuation
: 40 or 50 dB
Capacity
: 100 W or more
Frequency range
: 120–600 MHz
Output level
: 0.1 µV–32 mV
(–127 to –17 dBm)
Measuring range
: 10 mV–10 V
Frequency range
: DC–20 MHz
Measuring range
: 0.01–20 V
Input impedance
: 10 M
Ω/V DC or better
RF power m
e
ter
 1–100 W / 50 
Ω
Attenuator
40 dB or 50dB 
 
FM deviation meter
(DC measurable)
Oscillosco
pe
DC power supply
13.6 V/25 A [FR3000]
13.2 V/25 A [FR3100]
Standard signal 
generator
–127 to –17 dBm 
Frequency
 counter
JIG CABLE
[TX]
[RX]
[BATTERY] 
[MIC]
OPC-478 + OPC-592
RS-232C
connector
Audio 
generator
  Microphone connector
 
MIC GND
 MIC INPUT
– 
 PTT
1
8
 GND
AC
 millivoltmeter
Personal
computer
• 
CONNECTION