Features and Applications 
Page 4-64
Applications 
4
A 012 or 016 port (Release 4.0 and later) that is programmed as a generic 
VMI port or a MERLIN LEGEND MAIL Voice Messaging System port 
(including the Remote Maintenance Device port) can transfer an outside call 
to an outside number if the default settings are changed in Release 3.1 and 
later systems. In this case, a single-line telephone, connected to an 
integrated VMI port can complete trunk-to-trunk transfers. In Release 3.1 
and later systems, trunk-to-trunk transfer is automatically disallowed for all 
extensions, unless it has been enabled (on a per-extension basis) through 
system programming.
Calling restrictions (for example, Disallowed Lists, Toll Restriction, Facility 
Restriction Levels) should be programmed, as appropriate, to minimize toll 
fraud abuse, especially if a single-line telephone is connected to an 
integrated VMI port. Refer to the “Calling Restrictions” section in the 
Feature 
Reference 