DELL 7.4 用户手册

下载
页码 232
SNMP Trap 
Numbers
1203
Event ID — 2345
Description
The virtual disk initialization failed.
Severity
Critical / Failure / Error
Cause and 
Action
Cause: The controller cannot communicate with attached devices. A disk may be 
removed or contain errors. Cables may also be loose or defective.
Action: Verify the health of attached devices. Review the Alert Log for significant 
events. Make sure the cables are attached securely. See the Cables Attached 
Correctly section for more information on checking the cables.
Related Alert 
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2081
SNMP Trap 
Numbers
1204
Event ID — 2346
Description
Error occurred: %1.
Severity
Warning / Non-critical
Cause and 
Action
Cause: A physical device may have an error. The %1 indicates a substitution 
variable. The text for this substitution variable is generated by the firmware and is 
displayed with the alert in the alert log. This text can vary depending on the 
situation.
Action: Verify the health of attached devices. Review the alert log for significant 
events. Run the PHY integrity diagnostic tests. You may need to replace faulty 
hardware. Make sure that the cables are attached securely. See the hardware 
documentation for more information.
Related Alert 
Information
Clear Alert Number: None
Related Alert Number: 2048, 2050, 2056, 2057, 2076, 2079, 2081, 2083, 2095, 
2129, 2201, 2203, 2270, 2282, 2369
Local Response Agent (LRA) Number: 2070
SNMP Trap 
Numbers
903
Event ID — 2347
Description
The rebuild failed due to errors on the source physical disk.
Severity
Critical / Failure / Error
157