Siemens M200D 用户手册
Product family
2.3 Design concept
M200D AS-Interface Basic
16
Manual, 03/2009, A5E01668085-01
2.3.1
Operator controls
The motor starter is equipped with the following operator controls:
①
Key-operated switch (order variant)
②
Keypad (order variant)
③
Disconnecting means (circuit breaker)
④
Cover for parameter setting elements
Integrated manual local control (key-operated switch ① and keypad ②; order variant)
A key-operated switch and keypad are used for local operation.
The key can be inserted/removed in three positions.
Disconnecting means ③ (circuit breaker)
The disconnecting means is designed for the following individual functions:
● Disconnecting the series-connected consumers from the supply voltage
● Short-circuit protection of the series-connected consumer
● Switching on inhibited via padlock (max. three padlocks possible)
● Disconnecting the series-connected consumers from the supply voltage
● Short-circuit protection of the series-connected consumer
● Switching on inhibited via padlock (max. three padlocks possible)
Parameter settings ④
The following setting elements can be found under the cover of the M200D AS-i Basic:
● Rotary coding switch for:
● Rotary coding switch for:
– Setting the rated operating current
– Deactivating the thermal motor model (class OFF)
– Deactivating the thermal motor model (class OFF)
● DIP switch for:
– Autoreset (ON / OFF)
– Connector monitoring (ON / OFF)
– Temperature sensor (ON / OFF)
– Temperature sensor (PTC / TC)
– Connector monitoring (ON / OFF)
– Temperature sensor (ON / OFF)
– Temperature sensor (PTC / TC)