AT&T 555-230-894 用户手册

下载
页码 332
Test Tone-Clock Interchange for each Expansion Port 
Network (EPN)
Issue 1  September 1995 
8-17
Test Tone-Clock Interchange for each
Expansion Port Network (EPN)
If the system is set up with Critical Reliability, test the Tone-Clock interchange for 
each Expansion Port Network (EPN).
1. Verify the screen displays:
command:
2. Type status system all-cabinets and press 
ENTER
.
This displays the location of the Standby Tone-Clock.
3. Type set tone-clock xx where xx is the Port-Network/Carrier for the 
Standby Tone-Clock.  Press enter.
4. Type status system all-cabinets and press 
ENTER
.
5. Verify the duplicated Tone-Clock is active using the information displayed 
on the screen.
If any problems are indicated, check the Time Division Multiplexing (TDM) 
cables in the associated Expansion Port Network (EPN).
Test Expansion Interface Exchange for
Each Expansion Port Network (EPN)
If the system is set up with Critical Reliability, test the expansion interface 
exchange for each Expansion Port Network (EPN).
1. Verify the screen displays:
command:
2. Type status system all-cabinets and press 
ENTER
.
This displays the standby expansion link.