AT&T 555-230-894 用户手册

下载
页码 332
Installing the 9400-Series Telephones
E-2
September 1995 Issue 1  
NOTE:
The 3BIC and 3BEW protectors can be used 
only
 for 2-wire installations. 
They
 cannot 
be used for 4-wire installations.
These telephones are 
not 
for residential use. They are for business systems 
applications only. Use in a residential environment could result in an electrical 
short circuit when the telephone wiring is set up to provide other applications, for 
example, for appliance control or power transformers. The AC power used in 
these applications may create a safety hazard by placing a direct short circuit 
across the telephone wiring.
Wiring Information
The 9403 and the 9434 telephones work in both 2-wire and 4-wire configurations. 
The 9410 telephone works 
only
 in the 2-wire digital communications protocol 
(DCP) configuration. Wiring is also discussed in Chapter 9, "Install and Wire 
Telephones and Other Equipment".
Figure E-1 and Figure E-2 show an enlargement of a telephone 8-pin line jack in 
a 2-wire and a 4-wire configuration, respectively. Table E-1 below these figures 
describes the pins on this jack.
Figure E-1 shows power requirements in a 2-wire installation. Switch connections 
must be on pair 1 (Pins 4 and 5).
Figure E-1.
A Telephone Line Jack in a 2-Wire Configuration
Figure E-2 shows power requirements in a 4-wire installation. Switch connections 
must be on pair 2 (Pins 1 and 2) and pair 3 (Pins 3 and 6).
1 2 3 4 5 6 7 8