The Oxygen Limit Fraction (OLF%) displays only the value of the higher of the two
calculations. The oxygen toxicity calculations are based on the factors listed in Sec-
tion 10.3. Oxygen exposure 
.
6.2.4. Gas change and multiple breathing gas mixes
One of the special features in Suunto D6i is the possibility to set an additional nitrox
mix to be used during a dive. This feature can be activated by setting the Mix2 as a
Primary (or Secondary) gas, and entering other parameters in the same way as with
the Mix1 gas. Mix2 settings are held until you change them (they will not return to
default settings automatically). A dive is always started with Mix1. During the dive, the
Suunto D6i enables you change to another enabled mix, which is within the set max-
imum oxygen partial pressure. The tissue calculation during the dive is based on the
mixes you have selected as Primary gases.
The Suunto D6i allows gas changes to enabled gas mixes during the dive. Gas changes
are made by following the procedure below:
CHANGING GAS MIX. 
SCROLL THROUGH 
ENABLED MIXES BY 
PRESSING THE UP OR 
DOWN BUTTONS. SELECT 
NEW MIX BY PRESSING 
THE SELECT BUTTON.
84