Philips P89LPC907 用户手册

下载
页码 110
Philips Semiconductors
User’s Manual - Preliminary -
P89LPC906/907/908
UART
2003 Dec 8     
60
SFR SPACE
The UART SFRs are at the following locations:
Table 8-1: SFR Locations for UARTs
BAUD RATE GENERATOR AND SELECTION
The  enhanced UART has an independent Baud Rate Generator. The baud rate is determined by a value programmed into the 
BRGR1 and BRGR0 SFRs. The UART can use either Timer 1 or the baud rate generator output as determined by BRGCON.2-
1 (see Figure 8-2). Note that Timer T1 is further divided by 2 if the SMOD1 bit (PCON.7) is cleared. The independent Baud Rate 
Generator uses CCLK.
UPDATING THE BRGR1 AND BRGR0 SFRS
The baud rate SFRs, BRGR1 and BRGR0 must only be loaded when the Baud Rate Generator is disabled (the BRGEN bit in 
the BRGCON register is ’0’). This avoids the loading of an interim value to the baud rate generator. (CAUTION: If either BRGR0 
or BRGR1 is written when BRGEN = 1, the result is unpredictable.)
 
Table 8-2: Baud Rate Generation for UART
Register
Description
SFR Location
PCON
Power Control
87H
SCON
Serial Port (UART) Control
98H
SBUF
Serial Port  (UART) Data Buffer
99H
SADDR
Serial Port  (UART) Address
A9H
SADEN
Serial Port  (UART) Address Enable
B9H
SSTAT
Serial Port  (UART) Status
BAH
BRGR1
Baud Rate Generator Rate High Byte
BFH
BRGR0
Baud Rate Generator Rate Low Byte
BEH
BRGCON
Baud Rate Generator Control
BDH
SCON.7 
(SM0)
SCON.6 
(SM1)
PCON.7 
(SMOD1)
BRGCON.1
 (SBRGS)
Receive/Transmit Baud Rate for UART
0
0
X
X
CCLK/16
0
1
0
0
CCLK/(256-TH1)64
1
0
CCLK/(256-TH1)32
X
1
CCLK/((BRGR1,BRGR0)+16)
1
0
0
X
CCLK/32
1
X
CCLK/16
1
1
0
0
CCLK/(256-TH1)64
1
0
CCLK/(256-TH1)32
X
1
CCLK/((BRGR1,BRGR0)+16)