JWN-SeRIeS RIDe-ON pOWeR TROWeL • OpeRaTION maNuaL — Rev. #1 (05/12/12)  — page 21
ImpORTaNT INFORmaTION BeFORe yOu STaRT
1.  This  ride-on  trowel  is  equipped  with  a  safety  stop 
switch. This  switch  is  located  beneath  the  seat 
assembly. Remember the engine will not start unless 
an operator is sitting in the operator’s seat. The weight 
of an operator depresses an electrical switch which 
will allow the engine to start.
2.  The  safety  stop  switch  should  be  used  to  stop  the 
engine  after  every  use.  Doing  this  will  verify  the 
switch  is  working  properly  thus  providing  safety  for 
the operator. Remember to turn the key to the “OFF” 
position after stopping the machine. Not doing so will 
drain the battery.
3.  The  right  foot  pedal  (Figure  9)  controls  blade  and 
engine speed. The position of the foot pedal determines 
the  blade  speed.  Slow  blade  speed  is  obtained  by 
slightly depressing the pedal. Maximum blade speed 
is obtained by fully depressing the pedal.
Figure 9. Blade Speed Control Foot Pedal
STaRTINg THe eNgINe
1.  With one foot on the ground and the other foot placed 
on the trowel's platform, grab the frame near the seat 
and lift yourself onto the trowel. Sit in the operator's seat 
and ensure the control handles, foot pedal and control 
panel items can be comfortably accessed.
2.  When  starting  a  cold  engine,  pull  the  choke  knob, 
(Figure 10) out to the closed position. In warm weather 
or when the engine is warm, the unit can be started 
with choke halfway or completely open.
 WaRNINg
NeveR disable or disconnect the safety stop switch. It is 
provided for the operator's safety and injury or death may 
result if it is disabled, disconnected or improperly maintained.
OperatiOn
Figure 10. Choke Knob
3.  Keep your foot OFF the blade speed control pedal and 
in all circumstances, start the engine at idle (without 
touching the pedal).
4.  Insert the ignition key into the ignition switch. 
5.  Turn the ignition key (Figure 11) clockwise and listen 
for the engine to start. Once the engine starts release 
ignition key.
6.  If the engine fails to start in this manner, consult the 
engine owner's manual supplied with the trowel.
7.  Test the safety stop switch by standing up briefly. The 
switch under the seat should cause the engine to stop. If 
the switch fails to shut down the engine, turn off the engine 
with the key switch and repair the safety stop switch. See 
the Troubleshooting section for possible causes.
Figure 11. Ignition Key
8.  Let the engine idle for 3-5 minutes. If choke is applied, 
push the choke to the open position as soon as the 
engine will run smoothly.
CHOKE
KNOB
CLOSED
OPEN
IGNITION
KEY
START
OFF