FIREPLAcE INSTALLATION
Continued
Figure 29 - Blower Wiring Diagram for Thermostat-Controlled 
Models
4.  Be certain that all wire terminals are securely attached to ter-
minals on blower motor and thermal switch, and that the screw 
for the thermodisc bracket and green ground wire is tight. 
5.  Mount the speed control box against the mounting plate provided 
in the lower fireplace cavity by placing the plastic control shaft 
forward through the round hole (see Figure 26, page 15).
6.  While supporting speed control, secure control shaft with lock 
nut by pushing and turning lock nut with pliers clockwise until 
it is tight against mounting plate. Place control knob provided 
on shaft (see Figure 26, page 15).
7.  Check to make sure that the power cord is completely clear of 
the blower wheel and that there are no other foreign objects in 
blower wheel. Also double check all wire leads and make sure 
wire routing is not pinched or in a precarious position. Correct 
accordingly.
8.  Turn on power to duplex outlet if previously turned off per the 
warning in column 2, page 14.
9.  Plug in blower power cord to duplex outlet.
10.  The blower will only run when the speed control knob is in the 
ON position and the thermal switch senses temperature after the 
fireplace begins to heat up. The blower speed can be adjusted by 
rotating the control knob. To turn off, turn knob fully counterclock-
wise until it clicks off. If the blower is ON and has been running 
with the fireplace operating, the blower will continue to run for a 
short time after the fireplace has been turned off. As the thermal 
switch cools down, the blower shuts down automatically.
11.  Peel off the backing paper and stick the supplied wiring diagram 
decal on the firebox bottom approximately 12" in front of the 
blower (see Figure 27, page 15).
blower Wiring Diagram
  CAUtION:  Label  all  wires  prior  to  disconnection 
when servicing controls. Wiring errors can cause im-
proper and dangerous operation. Verify proper opera-
tion after servicing.
INStALLING GAS PIPING tO FIREPLACE 
LOCAtION
 WARNING: A qualified service person must connect 
fireplace to gas supply. Follow all local codes.
  CAUtION:  For  propane/LP  units,  never  connect 
fireplace directly to the propane/LP supply. this heater 
requires  an  external  regulator  (not  supplied).  Install 
the external regulator between the fireplace and pro-
pane/LP supply.
Installation Items Needed
Before installing fireplace, make sure you have the items listed below.
•  external regulator (supplied by installer)
•  piping (check local codes)
•  sealant (resistant to propane/LP gas)
•  equipment shutoff valve *
•  test gauge connection *
•  sediment trap
•  tee joint
•  pipe wrench
•  approved flexible gas line with gas connector (if allowed by local 
codes)
* A CSA design-certified equipment shutoff valve with 1/8" NPT tap 
is an acceptable alternative to test gauge connection. Purchase the 
CSA design-certified equipment shutoff valve from your retailer.
For  propane/LP  connection  only,  the  installer  must  supply  an 
external  regulator. The  external  regulator  will  reduce  incoming 
gas pressure. You must reduce incoming gas pressure to between 
11" and 14" of water. If you do not reduce incoming gas pressure, 
fireplace regulator damage could occur. Install external regulator 
with the vent pointing down as shown in Figure 30. Pointing the 
vent down protects it from freezing rain or sleet.
 CAUtION: Use only new, black iron or steel pipe. 
Internally-tinned copper tubing may be used in certain 
areas. Check your local codes. Use pipe of 1/2" diameter 
or greater to allow proper gas volume to fireplace. If 
pipe is too small, undue loss of volume will occur.
Figure 30 - External Regulator with Vent Pointing Down 
(Propane/LP Only)
Propane/LP 
Supply Tank 
External 
Regulator 
Vent 
Pointing 
Down
Blue
Variable
Fan Switch
Fan Switch
(N.O.)
Green
White
On
110/115 
V.A.C.
Blower
Motor
Black 
Off
1
2
Black