Radiance Direct Vent Gas Heater
20012697
ST651
Fig. 23  Simpson Dura-Vent - install outer adapter pipe. 
ST652
dura vent
attach outer assy
4/20/01   djt
ST649
dura vent
attach inner assy
4/20/01   djt
CEMENT
ST649
Inner Adpater Pipe
1/4-20 x 
3/8” Phil-
lips Screws
Fig. 22  Simpson DuraVent - install inner adpater pipe.
Install Vent Adapter Pipe
(Selkirk Corporation Vent Components)
The appliance adapter (AA) adapts DIRECT-TEMP to 
most direct vent appliances incorporating outlet col-
lars configured to receive most common 4” (ID) by 6⁵⁄₈” 
(OD) or 5” (ID) by 8” (OD) “Twist Lock” style, direct vent 
systems.
The adapter incorporates two indentations on the outer 
wall of the inlet end, which are designed to “Twist Lock” 
into place upon attachment to the appliance outlet. Align 
the adapter indentations with the entry slots of the appli-
ance outlet and slide together. Turn the adapter clock-
wise approximately one-quarter turn to lock in place. 
The outlet end of the adapter is standard DIRECT-
TEMP construction.
For connection of Direct-Temp to units with 4” x 7” flue 
outlets, the following methods have been approved:
• 
Install the Universal/Napoleon Appliance Adapter 
4DT-AAN.
• 
Connect a standard Direct-Temp pipe length (do 
not use an adjustable length in this application) a 
minimum of 1¹⁄₂” over the flue outlet. The outside of 
the Direct-Temp Length will fit inside the flue outlet 
Secure with a minimum of two #8 x 1/4” sheet metal 
screws and seal with hi-temp silicone.
For units factory equipped with appliance adapters from 
other brands of Direct Vent systems, it is permissible 
to simply slide a length of DT pipe over the appliance 
adapter. Secure with a minimum of two #8 x 1/4” sheet 
metal screws and seal with hi-temp silicone.
Side Wall Termination Assembly
1.  Locate the vent opening on the wall. Refer to Page 
6, Figure 5, to determine the opening centerline. 
It may be necessary to first position the stove and 
measure to find the hole location. Depending on 
whether the wall is made of combustible materials, 
cut the opening to the size shown in Figure 24. Com-
bustible wall openings must be framed as shown in 
Figure 24.
VO584-100
Vent Opening
2/99   djt
9³⁄₈”
(240mm)
7¹⁄₂”
9³⁄₈”
(240mm)
Framing Detail
Combustible Wall
Noncombustible 
Wall
VO584-100
Fig. 24   Locate vent opening.
CFM System
DuraVent 
System
10”
(254mm)
10”
(254mm)
NOTE: When Dura-Vent firestop is installed, 
leave air space on top side of cut out.
2.  Measure the wall thickness and cut the wall sleeve 
sections to proper length (MAXIMUM 12”). Assemble 
the sleeve with the #8 sheet metal screws supplied. 
Attach the firestop plate to the sleeve end with the 
holes. (Fig. 25)   NOTE: The wall sleeve is required 
in combustible walls only.
3.  Install the Wall Firestop/Sleeve assembly into the 
wall cutout and fasten the firestop to the wall cutout 
framing members. (Fig. 25)
For DuraVent pipe only: Install vent pipe by align-
ing the locking system together, sliding the pipes 
together and twisting clockwise.
  •
 Install 90° elbow. Twist lock as before.
  • 
Slide the wall plate over horizontal run before at-
taching the horizontal run to the elbow. Fasten wall 
plate to wall.