1. Extremely long runs and numerous turns in the duct leading from the fireplace to the combustion air
assembly should be avoided.  These conditions will increase the resistance to the free flow of air through
the duct.  Refer to Figures 1 and 27 for methods of installing the outside air for combustion assemblies.
2. The combustion air assembly should be located at an exterior location, which is not likely to be accidentally
blocked in any manner.  The assembly should be located above the snow line to prevent blockage by snow
accumulation.
3. The combustion air inlet assembly should never be mounted in a garage or storage area where combustible
fumes such as gasoline might be drawn into the fireplace.
4. Combustion air can be drawn from the crawl space under a house when an adequate supply of air is
provided by open ventilation.
5. Do not take combustion air from attic space or garage space.
CONCRETE SLAB
CONCRETE SLAB
INSTALLATION 
INSTALLATION 
(OPTIONAL OUTSIDE
(OPTIONAL OUTSIDE
AIR RUNS)
AIR RUNS)
INLET GRILLE
INLET GRILLE
   IN SOFFIT
   IN SOFFIT
(OVERHANG)
(OVERHANG)
8' MAX.
8' MAX.
FIRESTOP SPACER
FIRESTOP SPACER
CAUTION:DO NOT TAKE 
CAUTION:DO NOT TAKE 
COMBUSTION AIR FROM
COMBUSTION AIR FROM
ATTIC SPACE OR GARAGE. 
ATTIC SPACE OR GARAGE. 
TERMINATION CAP
TERMINATION CAP
INSTALLATION ABOVE BASEMENT
      OR CRAWL SPACE
      OR CRAWL SPACE
FIRESTOP SPACER
FIRESTOP SPACER
TO OUTSIDE WALL
TO OUTSIDE WALL
DUCT EXTENDED
DUCT EXTENDED
TO MISS JOIST
TO MISS JOIST
SECOND FLOOR 
SECOND FLOOR 
45˚ CORNER
 CORNER
INSTALLATION
INSTALLATION
ON SLAB FLOOR
ON SLAB FLOOR
(ONE WALL,
(ONE WALL,
INSIDE ROOM)
INSIDE ROOM)
INSIDE
WALL
WALL
OUTSIDE
OUTSIDE
WALL
WALL
ABOVE
ABOVE
SNOW
SNOW
LEVEL
GROUND 
GROUND 
LEVEL
BASEMENT 
BASEMENT 
WALL
WALL
PLATE
BASEMENT INSTALLATION
BASEMENT INSTALLATION
F
IGURE
 27