SAFETY INFORMATION
THIS GAS APPLIANCE IS DESIGNED FOR OUTDOOR USE ONLY.
IT IS NOT INTENDED FOR INSTALLATION IN ANY BUIDING,
GARAGE.OR ENCLOSED STRUCTION. IT IS NOT INTENDED FOR
INSTALLATION IN OR ON RECREATIONAL VEHICLES OR BOATS.
 
 
 
 
 
 
 
 
 
 
WARNING: Follow all gas leak procedures in
this manual, prior to operation.
 
 
 
 
 
 
 
 
 
 
WARNING
: Fuels used in gas fired appliances,
and the products of combustion of such fuels,
contain chemicals know to the State of California
to cause cancer, birth defects and /or other
reproductive harm. This warning is issued pursuant
to California Health & Safety Code Sec.25249.1
DO NOT ATTEMPT TO DISCONNECT THE GAS OR ANY
GAS FITTING WHILE THIS APPLIANCE IS IN OPERATION
.
Inspect the gas connections of this appliance prior to
each use. Do not operate the unit if there is a gas leak
present.
Do not   put anything flammable, on or around or be-
neath the campfire.
NEVER  Leave the campfire unattended while in
operation.
NEVER Allow children to operate this appliance.
NEVER Lean over the campfire or place ,hand or fin-
gers on the screen cover or near flame.
NEVER
  
Use liquid propane gas in a natural gas unit,
or natural gas in a liquid propane unit. Gas conver-
sions
 
SHOULD ONLY BE DONE BY A QUALIFIED
SERVICE TECHNICIAN. DO NOT
 
use charcoal bri-
quettes or lighter fluid in any campfire.
Storage of this appliance indoors is permissible only if
the gas is disconnected.
PROPER CLEARANCES FROM COMBUSTIBLE, CON-
STRUCTION AND MATERIALS MUST BE MAINTAINED
FROM ALL SIDES, TOP AND BOTTOM OF THIS
APPLIANCE.
 THIS APPLIANCE SHOULD
 
NEVER
 
BE PLACED ON
ANY COMBUSTIBLE SURFACE.
THIS APPLIANCE SHOULD NEVER BE PLACED UNDER
ANY COMBUSTIBLE CONSTRUCTION OR MATERIALS.
THIS APPLIANCE SHOULD  NEVER BE PLACED
CLOSER
 
THAN FORTY-EIGHT (48”) INCHES FROM
ANY SIDE TO ANY COMBUSTIBLE CONSTRUCTION
OR MATERIALS.
Location
Your campfire can be installed on a flat, stable surface,
away from any combustible materials or construction.
(See FIgure 13)
Place unit on any level, outdoor, non combustible
surface.
NOTE: Do not place this appliance on grass or dirt
area , this may prevent proper venting.
 HARD PIPING TO UNIT WITHOUT GAS PROXIMITY
1. TURN OFF THE GAS SUPPLY SYSTEM
     NOTE: All gas connections (except for brass to
     brass) require the following:
     Clean pipe threads using either a wire brush or steel
      wool. Apply Teflon tape or pipe dope to the steel
      fittings before making any connection.
      BE CAREFUL! Make sure all gas connections are
      snug, but not over tighten!
2. Extend the gas supply system using1/2”  black iron
pipe from current house supply. This may be ac-
complished by a teeing off” or tapping into a con-
venient gas line connection; installing the neces-
sary pipe for the distance required; and then in-
stalling a manual valve at exterior house wall. If
pipe is to pass though a foundation or house wall,
make sure to re-seal the area around the pipe with
weather sealant.
3.  From manual valve, extend piping to the campfire.
While this appliance is not in use, the gas must be
turned off at the gas supply.
While this appliance is not in use, it should be covered
to protect it from weather and other adverse elements.