Precor P30 Console 用户手册

下载
页码 104
Setting Up the Console 
27
 
 
 
Product  Value 
Information provided 
All 
EVENT LOG 
Displays any event codes that may 
have been detected by the software. 
For more information, refer to Event 
Log. 
Event Log 
The event log holds a maximum of 30 events. After the log 
reaches 30 events, older events are erased to make room for 
newer ones.   
Each event log entry contains the following information: 
 
Event number 
 
Odometer value when the event occurred 
 
Hour meter value at the time the event occurred 
 
Current drawn by the motor when the event occurred 
(treadmill only) 
The following table contains a list of events detectable by the 
software. 
Table  5.  Event log numbers and descriptions 
Event 
Number 
Description of Event 
00 
Upper PCA memory location event 
02 
RAM location event 
03 
EEPROM checksum event 
05 
Depressed key at power up 
09 
Lower PCA memory test event 
10 
Line Frequency out of acceptable range 
11 
Watchdog (Upper PCA) low voltage power 
12 
Watchdog (Lower PCA) low voltage power 
13 
Fan at incorrect speed (version 1 treadmills) 
14 
Fan fail (Lower PCA) 
15 
AC input voltage too high 
16 
AC input voltage too low 
20 
Too many maximum power requests in one second 
21 
Too many maximum consecutive power requests 
22 
No motor pulses at start up