Electrical Output
Electrical Output
Electrical Output
Electrical Output
Online Regulation
Online Regulation
Online Regulation
Online Regulation
-10% to +6% of nominal voltage
On battery Regulation
On battery Regulation
On battery Regulation
On battery Regulation
±5% of nominal voltage
Voltage Wave Form
Voltage Wave Form
Voltage Wave Form
Voltage Wave Form
Sine wave
Connections
Connections
Connections
Connections
See Model Specifications
Output Protection
Output Protection
Output Protection
Output Protection
Re-settable circuit protectors
Battery
Battery
Battery
Battery
Type
Type
Type
Type
Maintenance-free, sealed, valve-regulated lead acid (VRLA)
Recharge Time
Recharge Time
Recharge Time
Recharge Time
<3 hours to 90% usable capacity; <24 hours for complete recharge
Battery String Voltage
Battery String Voltage
Battery String Voltage
Battery String Voltage
T750 G2 and T750J: 24V (2x12V)
T1000 G3: 24V (2X12V)
T1000J: 36V (3x12V)
T1500 G3 and T1500J: 36V (3X12V)
Battery Ampere Hour
Battery Ampere Hour
Battery Ampere Hour
Battery Ampere Hour (ah) T750 G2: 7.2ah
T750J: 9ah
T1000 G3 and T1000J: 9ah
T1500 G3 and T1500J: 9ah
Communications
Communications
Communications
Communications
Serial Ports
Serial Ports
Serial Ports
Serial Ports
Standard communication port (ships with 6' Serial communication cable)
USB Port
USB Port
USB Port
USB Port
Standard communication port (ships with 6' USB communication cable)
LED Indicators
LED Indicators
LED Indicators
LED Indicators
Power On/Off button
Alarm Acknowledgement - Turns off the alarm buzzer.
Power LED
Green- AC is present
Battery LED
Amber- The unit is running off of the battery.
Overload LED
Red - Output is overloaded.
Service LED
Red- Faulty battery or battery failed test.
Audible Alarm- The unit detects an operational fault or changes in the
battery mode.
Environmental and
Environmental and
Environmental and
Environmental and
Safety/EMC
Safety/EMC
Safety/EMC
Safety/EMC
Operating Temperature
Operating Temperature
Operating Temperature
Operating Temperature
32° to 104° F (0° to 40° C)
Transit and Storage
Transit and Storage
Transit and Storage
Transit and Storage
Temperature
Temperature
Temperature
Temperature
-5° to 131° F (-15° to 55° C)
Relative Humidity
Relative Humidity
Relative Humidity
Relative Humidity
(Operating)
5% to 95% (non-condensing)
Operating Altitude
Operating Altitude
Operating Altitude
Operating Altitude
Up to 4921 feet (1500 Meters) above sea level
Audible Noise
Audible Noise
Audible Noise
Audible Noise
Less than 45 dBA max
Safety Markings
Safety Markings
Safety Markings
Safety Markings
UL, GS, S Mark, NOM, EK, GOST, TISI
EMC Markings
EMC Markings
EMC Markings
EMC Markings
CE, FCC, ICES, C-Tick, VCCI
Surge Suppression
Surge Suppression
Surge Suppression
Surge Suppression
Conforms to IEC 61000-4-5, Level 3EEE 587B and ANSI C62.41
Emissions
Emissions
Emissions
Emissions
FCC CFR 47, Part 15 Class B, CISPR 22, EN55022
Immunity
Immunity
Immunity
Immunity
EN55024, EN62040-2
QuickSpecs
HP Tower UPS T750 G2, T1000 G3, T1500 G3
HP Tower UPS T750 G2, T1000 G3, T1500 G3
HP Tower UPS T750 G2, T1000 G3, T1500 G3
HP Tower UPS T750 G2, T1000 G3, T1500 G3
Technical Specifications
DA - 13160   Worldwide — Version 7 — June 20, 2011