Mitsubishi Electronics E68 用户手册
12. POSITION
SWITCH
12.2
Canceling the Position Switch
II - 306
Rotation axis
Setting of dog1 and dog2
dog1, dog2 position
Description
dog1
< dog2
dog2 dog1
(Example)
dog1 =
30.000
dog2 = 330.000
A signal is output
between dog1 and
dog2.
between dog1 and
dog2.
dog1 dog2
(Example)
dog1 = -30.000
dog2 =
dog2 =
30.000
A signal is also output
when dog1 is negative.
when dog1 is negative.
dog1
> dog2
dog1 dog2
(Example)
dog1 = 330.000
dog2 =
dog2 =
30.000
A signal is output
between dog2 and
dog1.
between dog2 and
dog1.
⏐dog1 − dog2⏐ ≥ 360
dog2 dog1
(Example)
dog1 =
30.000
dog2 = 390.000
A signal is kept output
when the difference
between dog1 and dog2
exceeds 360 degrees.
when the difference
between dog1 and dog2
exceeds 360 degrees.
12.2 Canceling the Position Switch
To cancel the position switch‚ enter the number (#75 1) of the position switch to be canceled in # ( ) of the
setting field‚ enter a slash "/" in DATA ( )‚ then press the INPUT key. This deletes the axis name for the
specified position switch‚ thus invalidating the position switch.
The data specified for <dog1> and <dog2> are still stored in memory. To validate the position switch again‚
therefore‚ it is enough to specify the axis name only.
specified position switch‚ thus invalidating the position switch.
The data specified for <dog1> and <dog2> are still stored in memory. To validate the position switch again‚
therefore‚ it is enough to specify the axis name only.