GTO GP-SW050 用户手册

下载
页码 37
26
These two (2) terminals provide communication connections for dual gate applications where one
 
unit operates as a master and the other as slave operator.
Shielded twisted pair must be used. The shield (drain wire) connection should be connected at
Master Unit Only to the
LINK COM
 terminal but not both.
Connect the
DUAL LINK
terminals of the two operators together.
Connect the
LINK COM
terminals of the two operators together.
Set OPTIONS DIP Switch #2 and #3 accordingly.
If these terminals are not connected, each operator will automatically operate in single mode, if
DIP #3 is in MASTER position (OFF). If DIP #3 is set to the SLAVE position (ON) the unit is
 
non-functional.
Recommended Belden Wire®, 22 AWG, type 8761, 9461, 9451, 1266A or equivalent.
1-pair shielded with drain wire. Available at your local electrical supply store.
Dual gate link connection
installing a Dual gate operator system
IMPORTANT:   With a dual gate system certain control board settings and connections are required on the MASTER 
unit only and some are required on both the MASTER and the SLAVE unit. The list below gives an overview.
Gate Sequencing - DIP #2 on Master Unit
Alarms - wired to MASTER only
Entry Devices - can be wired to either unit
Adjustable Auto Close - MASTER controls opening and closing for both gates)
Locks - controlled by the MASTER unit
Setting Limits - set DIP#3 on each operator to MASTER position (OFF) in order to set the limit for each
gate. After the limit is set, DIP #3 can be set to SLAVE (ON) position for dual mode operation.
ALARM
STATUS
DUAL
LINK
AT OPEN
LIMIT
PRISON
MODE
+  ACC.  PWR.
12VDC
-  300ma
ALARM
STATUS
DUAL
LINK
AT OPEN
LIMIT
PRISON
MODE
+  ACC.  PWR.
12VDC
-  300ma
A
C
C.
 PO
WER
DU
AL C
ABLE
+12Vdc
COM
DUAL LINK
LINK COM
A
C
C.
 PO
WER
DU
AL C
ABLE
+12Vdc
COM
DUAL LINK
LINK COM
NOTE:  Do not combine AC and low voltage
wire in the same conduit.
Drain wire connects
at MASTER unit only.