System Issues
11
Upgrade
Considerations
There are three primary upgrade considerations:
Once you install software version 7.0.0 or higher in a system that uses 
a revision 8.0 motherboard, you can never install software versions 
previous to version 7.0.0 in the future. To see if you have a revision 8.0 
motherboard in your system, enter 
system display
 at the top level 
of the Administration Console. The first line of the display shows the 
product name and, in parentheses, the revision number of the 
motherboard.
If you are upgrading from a release prior to version 7.0.0, be aware 
that the menu item 
ip forwarding
 was changed to 
ip routing
 
at version 7.0.0. If you have created automated scripts that include 
ip forwarding
, edit them to reflect this command change.
If you are upgrading from a release prior to version 8.1.1, 
be aware that the parameter 
broadcast address
 in the IP 
interface definition procedure was changed to 
advertisement address(es)
 at version 8.1.1. If you have 
created automated scripts that include 
broadcast address
, edit 
them to reflect this command change.
Restrictions with
ATM and 10BASE-FL
Modules
Each CoreBuilder 2500 chassis features two slots for low-speed modules 
(Ethernet) and two slots for high-speed modules (ATM, FDDI, or Fast 
Ethernet). At this release, however, the system supports only one ATM 
module per chassis.
In addition, restrictions apply to certain configurations that mix one ATM 
module with two older Ethernet 10BASE-FL modules (3C201400; no 
longer orderable). The combination of these three modules causes certain 
systems to draw excessive power and eventually fail. Whether your 
system could be affected by this module-combination problem depends 
on the revision level of the system motherboard. 
You can order a newer version of the 10BASE-FL module (3C201400A). 
The configuration restrictions described in this section do not apply to this 
newer version of the 10BASE-FL module.
To determine the revision level of your system motherboard, enter 
system display
 at the top level of the Administration Console. The 
first line of the display shows the product name and, in parentheses, the 
revision number of the motherboard.