Novatel OM-20000041 用户手册
C
Commands Summary
MiLLennium GPSCard Software Version 4.50 Command Descriptions Manual Rev 1
105
LOG
Many different types of data can be logged using several different methods of triggering the log events. Every log
element can be directed to either the
element can be directed to either the
COM1
or
COM2
ports. If a selected log element is to be directed to all the ports,
then separate
LOG
commands are required to control them. The
ONTIME
trigger option requires the addition of the
period parameter and optionally allows input of the offset parameter. See Chapter 3 and Appendix D for further
information and a complete list of ASCII and Binary data log structures.
information and a complete list of ASCII and Binary data log structures.
The optional parameter {hold} will prevent a log from being removed when the
UNLOGALL
command is issued. To
remove a log which was invoked using the {hold} parameter requires the specific use of the
UNLOG
command.
The [port] parameter is optional. If [port] is not specified, [port] is defaulted to the port that the command was
received on.
received on.
Syntax:
Example:
log com1,posa,ontime,60,1,hold
The above example will cause the
POSA
log to be logged to
COM
port 1, recurring every 60 seconds, offset by one
second, and with the {hold} parameter set so that logging would not be disrupted by the
UNLOGALL
command.
To send a log only one time, the trigger option can be ignored.
Example:
log com1 posa
log posa
LOG
[port]
datatype
[
trigger]
[period]
[offset]
{hold}