Novatel OM-20000041 用户手册

下载
页码 276
I
Information Messages
MiLLennium GPSCard Software Version 4.50 Command Descriptions Manual Rev 1
239
Table 
I
-2
Type 1 !MSGA Types
TYPE 2 INFORMATION MESSAGES
The following is a list of information messages which are generated by the Command Interpreter in response to a
user’s input. This list is not necessarily complete, but it is the most accurate one available at the time of publication.
It is intended to be a trouble-shooting tool.
Log type
Message String
1000
Unknown MSGA Type
1001
Authorization Code Is Time Limited
1002+
Reserved For Future Use
Error Message
Meaning
All Ok
No errors to report.
Argument Must Be Hexadecimal (0-9,A-F) Pairs
An argument which is not hexadecimal was entered.
Argument Must Be Numeric
An argument which is not numeric was entered. 
Authorization Changes Not Available On This Card
An attempt has been made to change the Authorization Code on a card which is 
not an OEM card.
Authorization Code Entered Incorrectly
The checksum is incorrect for the Authorization Code.  The Authorization Code 
was most likely entered incorrectly.
Authorization Code Is Invalid
The existing Authorization Code is invalid. Please contact NovAtel GPS customer 
service for a new Authorization Code.
Can’t Change Authorization Code
The existing Authorization Code cannot be changed. Please contact NovAtel 
GPS customer service for assistance.
Clock Model not set TM1A rejected
The clock model status in a $TM1A command is invalid.  The $TM1A command 
is rejected when the clock model has not been set.
CLOCK_ADJUST Command Not Available On This 
Model
The CLOCKADJUST command is not available on this model.
Complete Almanac not received yet - try again later
The almanac cannot be saved because a complete almanac has not yet been 
received.  A SAVEALMA command should be performed at a later time when a 
complete almanac has been received. 
Data Too Large To Save To NVM
The configuration data being saved is too large.
Differential Corrections Not Available On This Model
This model does not have the ability to send or receive differential corrections.  
EXTERNALCLOCK Command Not Available On This 
Model
The EXTERNALCLOCK command is not available on this model.
FREQUENCY_OUT Command Not Available On 
This Model
The FREQUENCY_OUT command is not available on this model.
FROM port name too LONG
The FROM port name in a SETNAV command is too long.
Invalid $ALMA CheckSum
The checksum of a $ALMA command is invalid.
Invalid $DCSA CheckSum
The checksum of a $DCSA command is invalid.
Invalid $DEBUG Options
An invalid option was entered in the $DEBUG command.
Invalid $IONA CheckSum
The checksum of a $IONA command is invalid.
Invalid $PXYA CheckSum
The checksum of a $PXYA command is invalid.
Invalid $REPA CheckSum
The checksum of a $REPA command is invalid.
Invalid $RTCA CheckSum/CRC
The CRC of a $RTCA command is invalid.
Invalid $RTCM CheckSum
The checksum of a $RTCA command is invalid.
Invalid $TM1A CheckSum
The checksum of a $TM1A command is invalid.
Invalid $UTCA CheckSum
The checksum of a $UTCA command is invalid.
Invalid $VXYA CheckSum
The checksum of a $VXYA command is invalid.
Invalid ADJUSTCLOCK Option
An invalid CLOCKADJUST switch has been entered.
Invalid Baudrate
The bit rate in a COMn command is invalid.
Invalid Carrier Smoothing Constant
The carrier smoothing constant of the CSMOOTH command is invalid.