Section 28   Sampling Rate Converter 
Page 1654 of 2108 
 
R01UH0134EJ0400  Rev. 4.00 
 
 Sep 
24, 
2014 
SH7262 Group, SH7264 Group
Bit Bit 
Name 
Initial 
Value R/W Description 
FLF 
Flush Processing Status Flag 
Indicates whether flush processing is in progress or 
not. 
[Clearing conditions] 
  When flush processing has been completed. 
  When 1 has been written to the CL bit in 
SRCCTRL. 
  When 1 has been written to the SRCEN bit in 
SRCCTRL while SRCEN is 0. 
[Setting condition] 
  When 1 has been written to the FL bit in 
SRCCTRL. 
3 UDF 0 R/(W)*
1
Output FIFO Underflow Interrupt Request Flag 
Indicates that the output data FIFO is read when the 
number of data units in the output data FIFO is zero. 
[Clearing conditions] 
  When 0 has been written to the UDF bit after 
reading UVF = 1. 
  When 1 has been written to the CL bit in 
SRCCTRL. 
  When 1 has been written to the SRCEN bit in 
SRCCTRL while SRCEN is 0. 
[Setting condition] 
  When the output data FIFO is read while the 
number of data units in the output FIFO is zero.