Impinger I -–1000 Series Service Manual - Domestic 
21 
Air Pressure Switch 
Check for 120 VAC on both sides of switch. If 
voltage present on one side only, check for air tube 
blockage. Adjust air switch. If above fails, replace 
air pressure switch. 
Transformer, 24 VAC 
Check for 120 VAC to primary of transformer. 
Check for 24 VAC from secondary of transformer. If 
there is primary voltage, but no secondary voltage, 
replace transformer. 
(Model  1004  &  1005) 
For oven models 1004 and 1005, there is a 1 Amp 
fuse located between the 24 VAC output from the 
transformer and the coil of the burner motor relay. If 
there is 24 VAC output from the transformer, but no 
burner motor relay action, check fuse and fuse 
holder. Replace as necessary. 
Burner Motor Relay 
Delete burner motor relay refer to Section D, Page 
34. 
Burner Blower Motor 
Check for 120 VAC supply to burner blower motor. 
If 120 VAC is present and motor does not run, 
replace motor. WITH POWER OFF: turn blower 
wheel to check for locked rotor. 
NOTE: 
Centrifugal Switch of Burner 
Blower Motor 
Check for 24 VAC output from secondary of 
transformer. If voltage is present, check for 24 VAC 
at pin 6 and the ground bar on ignition control and 
valve assembly. If the burner blower motor is 
running and there is no voltage at pin 6 and the 
ground bar on the ignition control valve, replace the 
burner blower motor. 
Ignition Control and Valve 
Assembly 
Check for 24 VAC supply to the ignition control and 
valve assembly at pin 6 and the ground bar. If 
voltage is present, check for 24 VAC across pin #1 
and the ground bar (pilot valve). If voltage is not 
present, replace electronic control package. If the 
pilot valve is energized, check to see that the high 
voltage ignitor circuit is also energized. To check, 
disconnect the ignitor lead from the bottom of 
ignition control. Place female terminal of ignitor 
lead approximately 1/8" from terminal post on 
ignition control. Spark should jump the 1/8" gap. If 
no spark is present,
 
replace ignition control. 
No Pilot 
If the ignition control is supplied with 24 VAC, and 
the pilot valve (internal to valve assembly) and 
ignitor circuits are energized, visually check for pilot 
flame. This may be done by opening the small 
inspection door on the end of the burner, or by 
opening the main oven door and looking under the 
lower finger housings on the right side of the oven. 
If no pilot flame is visible, check the following. 
Pilot Shut-off Valve 
Check to see that pilot shut-off valve is open (shut-
off valve is located between ignition control and 
valve assembly and burner.) 
Pilot Tube 
Check for gas pressure at pilot tube. Disconnect 
pilot tube at burner and connect manometer to pilot 
tube. If no gas pressure is present, check for 
blockage in pilot tube or pilot shut-off valve. If these 
are clear, and there is gas supplied to the oven, 
replace the ignition control and valve assembly. 
For ovens with 
Johnson Controls 
Ignition Control 
 
(For ovens with 
Honeywell Ignition 
control, See Pg. 21)
 
Pilot Orifice 
If there is gas pressure at the pilot tube, check the 
pilot orifice for obstructions. Replace as need 
 
Burner Ignitor 
Check the burner ignitor head for any obstructions, 
also check for frayed or broken wire, any type of 
damage to spark gap (.100 in. 2.5 m.m.) If there is 
visible damage, replace ignitor assembly.