Alto-Shaam 1010ESG 用户手册
COMBITOUCH
TM
ESG SERIES • GAS INSTALLATION MANUAL • 22.
INSTALLATION
1-1/2” (41mm)
diameter connection
required
diameter connection
required
Condensate Pan
Clean Out
Clean Out
The oven must discharge through an indirect waste pipe by means of an air gap. The drain fitting is supplied
with a 1-1/2-inch (41mm) NPT thread.
with a 1-1/2-inch (41mm) NPT thread.
A union is required. Install a 1-1/2-inch (41mm) diameter connection, drain line and clamp into place.
The drain line must always be a positive gradient
away from the Combitherm oven and not more
than 12-inches (305mm) before an air gap.
The drain line must always be a positive gradient
away from the Combitherm oven and not more
than 12-inches (305mm) before an air gap.
NOTE:
In the U.S.A., this equipment is to be
installed to comply with the Basic Plumbing
Code of the Building Offi cials and Code
Administrators International, Inc. [BOCA],
and the Food Service Sanitation Manual of
the Food & Drug Administration [FDA].
Code of the Building Offi cials and Code
Administrators International, Inc. [BOCA],
and the Food Service Sanitation Manual of
the Food & Drug Administration [FDA].
If several units are to be connected to one drain
pipe, the dimensions of the pipe must be sufficient
to allow an unobstructed water drain system.
pipe, the dimensions of the pipe must be sufficient
to allow an unobstructed water drain system.
WATER VALVE
WATER DRAINAGE
NOTE:
THE SHUT-OFF VALVE
MUST BE IN THE OPEN POSITION
WHEN THE OVEN IS BEING USED.
MUST BE IN THE OPEN POSITION
WHEN THE OVEN IS BEING USED.
1-1/2" (41mm) diameter NPT
at back of oven
at back of oven
WASTE PIPE
1-1/2" to 2" minimum diameter
(c. 38mm to 51mm)
2" (51mm)
Air Gap
1-1/2” (41mm) diameter
NPT at back of oven
NPT at back of oven
WASTE PIPE
1-1/2” to 2” minimum diameter
(c. 38mm to 51mm)
2” (51mm)
Air Gap
SHUT-OFF VALVE SHOWN
IN THE OFF POSITION
IN THE OFF POSITION