Alto-Shaam 1010ESG 用户手册

下载
页码 33
COMBITOUCH
TM
 ESG SERIES • GAS INSTALLATION MANUAL • 5.
INSTALLATION
SITE INSTALLATION
POSITIONING REQUIREMENTS
q
  In order to ensure proper ventilation, a minimum 
distance of at least 6-inches (152mm) must be kept 
from the control panels side (left) of the oven and 
any adjoining surfaces.
NOTE:
  Additional clearance is needed for service 
access. A minimum distance of 18-inches is strongly 
recommended. If adequate service clearance is not 
provided, it will be necessary to disconnect the gas, 
water, and drain to move the oven with a fork lift for 
service access. Charges in connection with inadequate 
service access is not covered under warranty.
q
  Allow a minimum of 4-inches (102mm) from the 
right side of the oven to allow the door to open to at 
least a 90° angle. Fully opened, the door will extend 
up to a 225° angle If the oven is furnished with the 
retractable door option, allow a minimum clearance 
of 6-1/2 inches (165mm).
q
  Allow a minimum clearance of 4-inches (102mm) 
from the back of the oven for plumbing connections.
q
  Allow a 20-inch (500mm) clearance at the top of 
the oven for free air movement and for the steam 
vent(s) located at the top.
q
  Do not install the oven adjacent to heat producing 
equipment such as fryers, broilers, etc. Heat 
from such appliances may cause damage to the 
controls of the Combitherm. Minimum clearance 
recommended: 20-inches (500mm)
Place the Combitherm oven on a stable, non-
combustible level horizontal surface. For countertop 
models, the oven stand must be level. Level from front-
to-back and side-to-side by means of the adjustable 
legs. In addition, the overall height of the oven should 
be positioned so the operating controls and shelves may 
be conveniently reached from the front.
When placing a countertop  
model on an oven 
stand, position the oven 
legs on the outside of 
the positioning pins.
RETRACTABLE DOOR 
OPTION:  
6-1/2” (165 mm)
Positioning 
Pins
Positioning 
Pins