Eclipse Construction Features
Composite tank and high density polyethylene dent
and scratch resistant jacket.
No anode rod required.
Models are in two sizes with capacity of 85 or 105
gallons in 42 total variations.
Input options are: 12.4, 18, or 24 kW.
Voltage options are 208, 240 or 480 VAC in either
single phase or 3-phase and 277 VAC in single
phase only.
Element wattages are 3100, 4500 or 6000 in each of
the four voltages. The elements are low watt density
design (46, 67, 90 watts/sq. in.) with stainless
(Inconel) sheath.
The four Inconel elements are spaced on the front
along a vertical line for easy access.
The power control circuits use 2 surface mounted
thermostats and operate in two stages so that a
lower control thermostat is for the lower two
elements and an upper control is for the upper two
elements. The lower element will provide recovery
for all needs and the upper two will kick in
additionally for larger demands.
170º F maximum delivered temperature.
System Sentinel LED indicators are provided
for each element to show power on.
A switch is provided in the control circuit for
installation dry fire protection. See label.
A temperature and pressure relief valve is
installed on top of the unit.
3/4” full port, full flow brass drain valve.
Standards approved to UL 1453 and UL/NSF 005.
Eclipse Specifications
RECOVERY CAPACITIES
Recovery at various temperature rises
TEMPERATURE RISE
EQUIVALENT
MODEL NUMBER
INPUT KW
BTU/HR
UNITS
40°F
50°F
60°F
70°F
80°F
90°F
100°F
110°F
120°F
ME85-12
12.4
42,309
GPH
126
100
84
72
63
55
50
45
42
ME85-18
18
61,420
GPH
186
149
124
106
93
83
74
68
62
ME85-24
24
81,893
GPH
248
199
165
142
124
110
99
90
83
ME105-12
12.4
42,309
GPH
126
100
84
72
63
55
50
45
42
ME105-18
18
61,420
GPH
186
149
124
106
93
83
74
68
62
ME105-24
24
81,893
GPH
248
199
165
142
124
110
99
90
83
DIMENSIONAL INFORMATION
All dimensions shown in inches
CAPACITY
MAX. DELIVERED
WATER HEATER
WATER HEATER
HEIGHT TO
APPROX. SHIPPING
MODEL NUMBER
INPUT KW
GALLONS
TEMPERATURE
HEIGHT
DIAMETER
WATER CONNECTION
WEIGHT (LBS.)
ME85-12
12.4
85
170º
66-1/4
28-1/4
70-1/4
170
ME85-18
18
85
170º
66-1/4
28-1/4
70-1/4
170
ME85-24
24
85
170º
66-1/4
28-1/4
70-1/4
170
ME105-12
12.4
105
170º
66-1/2
30-1/4
70-3/4
185
ME105-18
18
105
170º
66-1/2
30-1/4
70-3/4
185
ME105-24
24
105
170º
66-1/2
30-1/4
70-3/4
185
ELECTRICAL CHARACTERISTICS
FULL LOAD CURRENT – IN AMPERES
NUMBER
ELEMENT
NUMBER
NUMBER
208V
240V
277V
480V
MODEL NUMBER
INPUT KW
OF ELEMENTS
WATTAGE
OF FUSES
OF THERMOSTATS
PHASE 1
PHASE 3
PHASE 1
PHASE 3
PHASE 1
PHASE 1
PHASE 3
ME85-12
12.4
4
3100
8
2
60
39
52
34
45
26
17
ME85-18
18
4
4500
8
2
87
57
75
50
65
38
25
ME85-24
24
4
6000
8
2
115
76
100
66
87
50
35
ME105-12
12.4
4
3100
8
2
60
39
52
34
45
26
17
ME105-18
18
4
4500
8
2
87
57
75
50
65
38
25
ME105-24
24
4
6000
8
2
115
76
100
66
87
50
35
Commercial water heaters