  Recommended Piping for Basic Installation
   
 
 
 
 
 
 
 
 
 
 
Gas Supply
3/4" Cold Water Supply Line
3/4" Hot Water Supply Line
Rinnai
Equipment List
Rinnai
Water Heaters
RIK-KIT (Optional)
(3/4" Fittings Include:
2 Unions, 2 Ball Valves,
2 Drain  Valves  and
1 Pressure Relief Valve.)
QTY
1
1
3/4" Gas Connection
For Building Fixtures
Pressure Relief Valve
3/4" Ball Valve
3/4" Union
Check Valve
S
Pressure Regulator
Circulating Pump
Solenoid Valve
Boiler Drain Valve
KEY
This is not an engineered drawing.  It is intended only as a guide and not
as a replacement for professionally engineered project drawings. This
drawing is not intended to describe a complete system.  It is up to the
contractor/engineer to determine the necessary components and
configuration of the particular system being installed. This drawing does
not imply compliance with local building code requirements.  It is the
responsibility of the contractor/engineer to ensure installation is in
accordance with all local building codes.  Confer with local building
officials before installation.
Condensate drain line
Condensate
drain
Refer to the Condensate 
section in the venting 
instructions 
Water 
drain 
plug 
Condensate 
trap drain plug 
Hot water 
drain plug 
Condensate 
drain line