Rinnai REU-KA2530FFUD-US 产品宣传页
RC80HPi (KA2530FFUD)
Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-364-8643 • www.rinnai.us
MC-91-1US (included)
Deluxe controller: MC-100V-1US (optional)
Bathroom controller: BC-100V-1US (optional)
MCC-91-1US (for commercial applications)
Deluxe controller: MC-100V-1US (optional)
Bathroom controller: BC-100V-1US (optional)
MCC-91-1US (for commercial applications)
Non-polarized two-core cable, minimum 22 AWG
• Flame failure - Flame Rod
• Boiling protection
• Boiling protection
• Combustion fan rpm check
• Over current - glass fuse (3 amp)
• Top of heater - 6 inches
• Over current - glass fuse (3 amp)
• Top of heater - 6 inches
• Front of heater - 6 inches *
• Sides of heater - 2 inches
• Top of heater - 2 inches
• Sides of heater - 2 inches
• Top of heater - 2 inches
• Front of heater - 6 inches *
• Sides of heater - 1/2 inches
• Sides of heater - 1/2 inches
Natural Gas: min 5” W.C.
max 10.5” W.C.
Propane Gas: min 8” W.C.
max 13.5” W.C.
Natural Gas: high fire 2.9” W.C. low fire 0.70” W.C.
Propane Gas: high fire 3.7” W.C. low fire 1.06” W.C.
Propane Gas: high fire 3.7” W.C. low fire 1.06” W.C.
Meets California and Texas NOx Emission Rules
Heat exchanger: 12 years* for residential and 5 years* for commercial and
hydronic applications; (10 years* if used with the Rinnai Hydronic Air
Handler); all other parts 5 years*; labor 1 year; (* 3 years if used as a
circulating water heater within a circulation loop, when the water heater is
in series with a circulation system, all circulating water flows through the
water heater and without an on-demand recirculation system). Refer to
the manual for complete warranty information.
hydronic applications; (10 years* if used with the Rinnai Hydronic Air
Handler); all other parts 5 years*; labor 1 year; (* 3 years if used as a
circulating water heater within a circulation loop, when the water heater is
in series with a circulation system, all circulating water flows through the
water heater and without an on-demand recirculation system). Refer to
the manual for complete warranty information.
DIMENSIONS
Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior
notice. Local, state, provincial and federal codes must be adhered to prior to installation.
notice. Local, state, provincial and federal codes must be adhered to prior to installation.
• Remaining flame (OHS)
• Thermal fuse
• Automatic frost protection
• Automatic frost protection
• Back of heater - 0 inches
• Bottom of heater - 12 inches
• From vent pipe - 0 inches
• Back of heater - 0 inches
• Bottom of heater - 12 inches
• From vent pipe - 0 inches
• Back of heater - 0 inches
• Bottom of heater - 12 inches
• From vent pipe - 0 inches
WEIGHT: 63.9 lb (29 kg)
Controller
Controller Cable
Safety Devices
Clearances from Combustibles
* 24 inches required for serviceability
Clearances from Non-combustibles
* 24 inches required for serviceability
Min. / Max. Gas Supply Pressure
Manifold Gas Pressure (inches W.C.)
NOx
Warranty
DIM DESCRIPTION
in (mm)
A Width
18.5
(470)
B
Depth
10.5 (266.9) *
C
Height - Unit
26.4 (670)
D
Height - with brackets
28.5 (723.2)
E
Hot Water Outlet - from wall
4.3 (110) *
F
Hot Water Outlet - from center
3.9 (100)
G
Cold Water Inlet - from wall
2.9 (74.6) *
H
Cold Water Inlet - from center
1.1 (27.7)
I
Gas Connection - from wall
3.9 (99) *
J
Gas Connection - from center
4.1 (103.2)
K
From base to gas connection
1.6 (40.2)
From base to cold connection
2.0 (50.2)
From base to hot connection
1.6 (41.2)
L
Condensate Dain - from wall
5.2 (132.6) *
M Condensate Drain - from center
7.7 (195)
* This is the minimum
dimension from the wall.
The wall bracket is
adjustable to allow an
additional 1.57 inches (40
mm).
dimension from the wall.
The wall bracket is
adjustable to allow an
additional 1.57 inches (40
mm).
L E
M
F
H
J
G I