Catalog No.:  2000.302D 
Effective:  11-15-07 
Replaces:  1-1-07
 
Hi Delta – Type H 
Models 302B-902B
  
Model            
 
 
 
RATES OF FLOW AND PRESSURE DROPS 
 
10°F 
T 20°F 
T
30°F 
T
Min. Flow
Max. Flow 
Model GPM 
P (ft) GPM P (ft) GPM P (ft) GPM P (ft) T GPM  P (ft)  
302B 51  3.2  25
<1.0
N/A
N/A
20
<1
25
90 9.8 6 
402B 
68 5.4 34 1.5 22  <1 20 <1 34 90 10.0 7 
502B 
85 9.2 42 2.3 28 1.1 21 <1 40 90 10.5 9 
652B 
N/A N/A 55 4.0 36 1.8 28 1.1 40 90 10.7 
12 
752B 
N/A N/A 64 5.5 42 2.5 32 1.6 40 90 11.0 
14 
902B 
N/A N/A 76 8.5 51 3.8 38 2.2 40 90 11.8 
17 
Basis is 20 GPM or 40°F 
∆T for minimum flow, 90 GPM for maximum flow. 
NOTE: Pump location 
varies based on model 
and application 
SPECIFICATIONS 
 
 
 
Approx.
MBTUH
A
G H 
K T  W
Amp. Shipping
Model
Input Output Width NPT NPT     
 
Draw Wt. 
(Lbs)
302B
300
252
36
3/4 2 5 
6  18
6
380
402B 399  335  43  3/4 2 6 
18-1/2
445 
502B 500  420  50 1-1/4 
2 6 
6 22  6 
545 
652B 650  546 60-1/2 1-1/4 
2 8 
27-1/4
590 
752B 750  630 67-1/2 1-1/4 
2 8 
30-3/4
675 
902B 900  756  78 1-1/4 
2 8 
6 36  7 
740 
Dimensions are in inches. 
NOTES:  1.  Rates shown are for natural or propane gas, and elevations up to 5,000 feet. For installation above 5,000 feet, please contact manufacturer. 
 
2.  Required natural gas pressure is 7 – 10.5” WC. Required propane gas pressure is 11 - 13” WC.
 