Raypak 399B 产品宣传页

下载
页码 2
Catalog No.:  2000.461A 
Effective:  07-21-10 
Replaces:  9-15-07
 
Job:  
         
 
Engineer:  
         
 
 
Contractor:  
         
 
 
Prepared By:  
         
 
 Date:   
         
   
Model:   
         
 
  Indoor/Outdoor:   
         
 
   MBTUH Input:   
         
 
 
 
100% Factory Fire Tested  
Efficiency: 84% 
Maximum Outlet Temperature: 230°F 
Minimum Non-Condensing Inlet Temperature: 105°F 
Thermal Shock Proof Heat Exchanger 
Limited Twenty-Year Thermal Shock Warranty 
Limited Ten-Year Closed-System Heat Exchanger 
Warranty 
PolyTuf Powder Coated Cabinet 
No Combustible Floor Shield Required 
Fan-Assisted 
Patented Burner Security Blanket 
 
 
 
Heat Exchanger 
ƒ
 H 
Stamp 
ƒ
 Headers 
 Glass-Lined Cast Iron – Standard  
 Bronze – Option A-1 
ƒ
  ASME Inspected and Stamped 
160 PSIG Working Pressure 
ƒ
  National Board Approved 
ƒ
 Fin 
Tubing 
 Copper – Standard  
 Cupro Nickel – Option A-3 
ƒ
  ASME Steel Tube Sheet 
ƒ
  Silicone High Temp O-Rings 
ƒ
  Pressure Relief Valve, ASME 
 45 PSIG – Standard on Model 399B  
 60 PSIG – Standard on Models 
499B-899B 
            PSIG – Optional 
ƒ
  Temperature and Pressure Gauge 
ƒ
 Water 
Connections 
 Left – Standard  
 Right – Option A-6 
 
Controls 
ƒ
  120V, 60Hz, 1 Phase Power Supply 
ƒ
  120/24V 60Hz Transformer 
ƒ
 100% 
Shut-Off/Lockout 
ƒ
  Hot Surface Ignition 
ƒ
  Remote Flame Sensor 
ƒ
  High Limit Control, Manual Reset 
ƒ
  On/Off Power Switch 
ƒ
  Manual Shut-Off, Front-Mounted Switch 
ƒ
 Flow 
Switch 
ƒ
  Blocked Vent Pressure Switch 
ƒ
  Combustion Air Proving Switch 
ƒ
  Pump Time Delay Relay 
ƒ
 Status 
Display 
Lights 
Gas Train 
ƒ
  Manual Gas Shut-Off Valve(s) 
ƒ
 Combination 
Valves 
ƒ
 Firing 
Mode 
 On/Off: Model 399B 
 2-Stage: Models  
499B-899B 
ƒ
 Fuel 
 Natural Gas  
 Propane Gas 
ƒ
  Design Certified - ANSI 
Z21.13/CSA 4.9 
 
Burner 
ƒ
  Ultra-Low NOx: Less than  
20 PPM 
 
Construction 
ƒ
 Indoor/Outdoor 
Construction 
ƒ
  Enclosed Front Controls 
 
Venting 
ƒ
 Vent 
Location 
 Top, Outdoor – Standard 
 Top, Indoor – Option D-20 
 Rear – Option D-14 
ƒ
  Vent Termination Cap  
 Outdoor D-11 
 Indoor, Horizontal D-15 
 Indoor, Vertical (by others) 
ƒ
  Extractor – Optional  
 By others 
 Not required 
Temperature Controls 
 B-2 
Tankstat, Single-Stage  
(100-200°F) 
 B-3 
Tankstat, 2-Stage (100-200°F) 
 B-6 
Aquastat, 2-Stage (100-200°F) 
 B-__  TempTracker Digital Controller,   
2-Stage (Loose) 
 B-__  TempTracker Digital Controller,   
4-Stage (Loose) 
 
Options 
 C-6  Ignition Module, Manual Reset 
 F-10  Low Water Cut-Off, Remote Probe 
 I-1 
High Limit Control, Auto Reset 
 P-      Pump:            HP, 120V, 1
∅, 60Hz 
Water Hardness:       GPG 
 
 
 Cast Iron 
 Bronze 
 Mounted 
 Loose 
 
 
 Front 
 Rear 
 P-26  Cold Water Start (See 2000.48) 
 S-1 
Low Gas Pressure Switch, Manual 
 S-2 
High Gas Pressure Switch, 
Manual 
 X-1  SureRack™ Kit 
 X-2  SureRack Add-on 
                      
 
 
Regulatory Agency Requirements 
             
 
 
        
Delta Limited™ - Type H
   Space Heating/Hot Water Boilers 
Models 399B-899B
Shown with outdoor  
air inlet and pump covers
Proudly Made in the U.S.A 
Delta Limited models not approved for use in California