Lightolier IS_CACS 产品宣传页

下载
页码 2
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
INSTALLATION OF STEM KIT ONTO CEILING  
(Fig. 1 & 2) 
(NOTE: If custom length is required see page 2.) 
 
1. Assemble STEM to BALL ALIGNER using set screws. Pull wires  
   through BALL ALIGNER leaving no less than 6" exposed.  
2. For sloped ceilings, position opening in CROSSBAR facing   
    upward. (Fig. 2) Install CROSSBAR using OUTLET BOX SCREWS.   
3. Place BALL ALIGNER of STEM into CROSSBAR through side 
    access hole. When seated the BALL ALLIGNER keyway will line up 
    with TAB on CROSSBAR. 
4. Slide SAFETY STRAP into position and secure in position with        
    screw. 
5. Make Connections.  Bare Copper and/or green insulation wire(s) 
    must be connected to SUPPLY GROUND.  Connect WHITE  
    LEAD to NEUTRAL (WHITE) SUPPLY LEAD.  Connect BLACK  
    LEAD to HOT SUPPLY LEAD.  Use wire nuts (local hardware 
    items).  Push spliced leads into outlet box. 
 
6. Slide CANOPY over CROSSBAR and push up against ceiling. 
7. Insert SUPPORT COVER onto stem, secure with LOCK WASHER 
    and LOCK NUT. 
 
FIG. 1
OUTLET BOX 
SCREWS
CROSSBAR
CANOPY
BALL ALIGNER
SAFETY STRAP
SUPPORT
COVER
SCREWS
STEM
LOCK NUT
LOCK WASHER
OCTAGON
OUTLET BOX
(BY OTHERS)
45° MAX.
FIG. 2
STEM
BALL ALIGNER
CROSSBAR
SAFETY STRAP
 COMPANY
631 Airport Road, Fall River, MA 02720 
READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE INSTALLING FIXTURE
This fixture is intended for installation in accordance with the National Electrical Code and local regulations.  To 
assure full compliance with local codes and regulations, check with your local electrical inspector before 
installation.  To prevent electric shock, turn off electricity at fuse box before proceeding. 
Retain these instructions for maintenance reference.
INSTRUCTION SHEET NO.
IS:CACS 
Page 1 of 2
A0604 
INSTALLATION PROCEDURE FOR: CEILING MOUNT STEM KIT CACS AND C4CS SERIES 
USED WITH CEILING MOUNT CYLINDERS (ORDER SEPARATELY) 
WARNING: 
USE ONLY FIXTURE PROVIDED BY LIGHTOLIER.  USE OF OTHER MANUFACTURES’ FIXTURES MAY VOID 
THE UNDERWRITERS LABRATORIES LISTING AND COULD CONSTITUTE A FIRE HAZARD.