Lightolier PLA2G9LP32U 产品宣传页

下载
页码 2
Paralyte 2424
PLA2G9LP32U
Page 2 of 2
2' x 2' Recessed Fluorescent, 3-1/8" Deep, 9 Cell Parabolic Louver
Static and Air Return 3 Lamp, T8, 1-5/8" U Lamp
Lightolier 
a Genlyte Thomas Company
www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2003 Genlyte Thomas Group LLC (Lightolier Division)
A0902
Section 2/Folio G50-55 Rev. A
Job Information
Type:
Options & Accessories
Prewiring: 3/8” factory prewired cable (three no. 18 AWG leads, 6’ long), 
Suffix: FF6, (Four no. 18 AWG leads, 6’ long), Suffix: FF14.
Fusing: Internal fast-blow fusing. Suffix: GLR.
Internal slow-blow fusing. Suffix: GMF.
Fluorescent Emergency Lighting System: Factory-installed emergency power
battery pack with charger and inverter, concealed in fixture channel. Operates one
fluorescent lamp at reduced light output for 90 minutes. Suffix: EM
Radio Interference Filter: 120 or 277 volt, 50 or 60 Hz.
One per fixture. Suffix: R. One per ballast. Suffix: B.
Electrical Options: Special wiring, fusing or dimming ballasts and installed
lamps are available, consult your Lightolier representative or factory.
T-Bar Spacer: If T-bar is less than 1-1/2” deep, order Catalog Number: STC.
2 each end is required.
Specifications
Performance: In an installation of 3 lamp, 31W luminaires in a room cavity ratio
of 1, with reflectance of 80% ceiling, 50% wall, 20% floor, the C.U. shall not be
less than 78. To prevent glare the VCP shall not be less than 79 either lengthwise
or crosswise (at 100fc level) and the average brightness at 65° shall not exceed
1078 footlamberts. To control veiling reflections, luminaire output in the 30° - 90°
zone shall not be less than 67.3%.
Air Return: Designed to provide optimum air return. Air is returned through the 
Specifications (continued)
lamp compartment for all ceiling systems and direct to plenum through slots in
slot grid and narrow grid ceiling systems.
Materials: Chassis parts are die-formed code gauge cold rolled steel. Housing
is embossed for rigidity with all edges turned up for safe handling. Louver is
pre-anodized aluminum (Coilzak or equal). rails hemmed over and housing ends
turned-in for safe handling.
Finish: Louver–semi-specular anodized low iridescence, vertical grain reflector
sheet. Cavity–white baked polyester minimum 86% reflectance. Phosphate
undercoating. Chassis exterior–black baked polyester enamel.
Electrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If
K.O. is within 3” of ballast, use wire suitable for at least 90°.
Labels: I.B.E.W./UL and ULc Listed.
Photometry
Model No. PLA2G9LP32U120O3
coefficients of utilization — zonal cavity method (effective floor cavity reflectance 0.20)
RF
20
20
20
RC
80
50
30
RW
70
50
30
50
30
10
50
30
10
1
81
78
76
74
72
70
71
70
68
2
76
71
67
67
64
62
65
62
60
3
70
64
69
61
67
54
69
56
53
4
65
57
52
55
61
47
53
50
47
5
60
51
46
49
45
41
48
44
41
6
55
46
41
44
40
36
43
39
36
7
51
42
36
40
35
31
39
34
31
8
47
37
31
36
31
27
36
30
27
9
43
33
28
32
27
23
31
27
23
10
40
30
25
29
24
21
28
24
21
visual comfort probability  (rated lumens per lamp 3150.)
room size
ceiling height
ceiling height
W
L
8.5
10.0
13.0
16.0
8.5
10.0
13.0
16.0
20
20
65
59
56
68
70
65
62
63
20
30
68
62
55
54
73
68
63
60
20
40
71
65
60
56
75
70
66
62
20
60
72
68
63
59
76
72
69
65
30
20
71
64
59
65
75
68
63
62
30
30
73
67
58
53
77
71
63
59
30
40
75
69
62
55
78
72
67
61
30
60
76
71
64
58
79
74
69
64
30
80
77
73
67
61
80
75
71
66
40
20
74
67
63
66
78
73
66
63
40
30
75
70
62
55
79
74
67
60
40
40
77
72
65
57
80
75
69
62
40
60
78
73
67
60
80
76
71
64
40
80
79
75
69
62
81
77
73
66
40
100
80
76
71
65
82
78
74
68
60
30
77
72
66
59
80
76
70
62
60
40
79
74
68
60
81
77
72
64
60
60
79
75
70
62
82
78
73
65
60
80
80
76
71
65
82
78
74
68
60
100
80
77
73
66
82
79
76
69
100
40
80
76
71
64
83
79
74
67
100
60
81
77
73
66
83
79
75
69
100
80
81
78
74
68
83
80
77
71
100
100
82
78
75
69
84
80
77
72
room cavity ratio
luminaries lengthwise
luminaries crosswise
LER = FP - 64.6 IW - 85.0   BF - 0.88
Comparative yearly lighting energy cost per 1000 lumens = $3.79
PL
Paralyte
2424:
3-1/8" Deep
Parabolic
Precision
Contoured Pre-
anodized
Aluminum
Louver
A
2
Fixture
Width
G
Ceiling Type:
G=Grid (lay-in T-bar)
9
Number of
Cells
Louver Finish:
= Low
Iridescence
Semi-specular
(standard)
= White Paint
P
Ballast Cover:
P=Dual V Reflector
3
Lamp
Quantity
2U
Lamp/
Fixture Length:
2U= T8, 1-5/8" U 
Lamp
(Nominal 24")
Voltage:
120 or 277
Options:
Add appropriate
suffix to catalog
Ballast Type:
<
20THD
<
10THD
1 & 2 Lamp Elec. T8
SO*
H
I
*
1–3 Lamp Elec. T8
O3*
H3*
LOL T8 Dimming
PS
*
*Instant Start Standard
Other dimming options. Consult factory.
ITL33754
LIGHTOLIER
PLA2G9LP32U120O3
THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES • FIELD PERFORMANCE MAY VARY FROM LABORATORY PERFORMANCE.
Ordering Information
Explanation of Catalog Number. Example: PLA2G9LP32U120O3GLR
Body Style:
A= Air Handling
/Static