Regency U39-NG1 用户手册

下载
页码 44
Regency
®
 U39 ULTIMATE Direct Vent Freestanding Gas Stove
35
1)  Push in gas control knob slightly and turn to “PILOT” position.
2)  Push in control knob all the way and hold  in until the pilot lights 
up. Continue to hold the control knob in for about 20 seconds 
after the pilot is lit. Release knob.
3) Push in gas control knob slightly and turn to "ON" position.
4) Turn ON the fl ame switch.
2) Wait fi ve (5) minutes  to clear out any gas. If you then smell gas 
STOP! follow “B” in the safety information above on this label. If 
you don’t smell gas, go to the next step.
3)  Turn knob  on gas control counterclockwise           to “PILOT”.
4) Push in control knob all the way and hold in.  Immediately push 
black button on spark igniter until pilot lights. Continue to hold the 
control knob in for about 1/2 minute after the pilot is lit. Release 
knob and it will pop back up. Pilot should remain lit. If it goes out, 
repeat steps 3) and 4). 
 
If knob does not pop up when released, stop and immediately call 
your service technician or gas supplier.
 
 If the pilot will not stay lit after several tries, turn the gas control 
knob to “OFF” and call your service technician or gas supplier.
5)  Turn gas control knob counterclockwise        to “ON”.
6)  Use rocker switch to operate main burner.
DO NOT REMOVE THIS INSTRUCTION PLATE
FOR YOUR SAFETY READ BEFORE LIGHTING
A)  This appliance has a pilot which must be lighted by  hand,  following  the  instructions below  exactly.
B)  BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the fl oor because some gas is heavier than 
air and will settle on the fl oor.
      WHAT TO DO IF YOU SMELL GAS
 
-  Do not try to light any appliance
 
-  Do not touch any electric switch, do not use any phone in your building
 
-  Immediately call your gas supplier from a neighbors phone. Follow the gas supplier’s instructions.
 
-  If you cannot reach your gas supplier, call the fi re department.
C)  Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to 
repair it, call a qualifi ed service technician. Force or attempted repair may result in a fi re or explosion.
D)  Do not use this appliance if any part has been under water. Immediately call a qualifi ed service technician to inspect the appliance and 
to replace any part of the control system and any gas control which has been under water.
E)  This appliance needs fresh air for safe operation and must be installed so there are provisions for adequate combustion and ventilation air.
918-474a
Gas Inlet
OFF
WARNING: If you do not follow these instructions exactly, a fi re or explosion may result causing property damage, 
personal injury or loss of life. Improper installation, adjustment, alteration, service or maintenance can cause 
injury or property damage. Refer to the owner’s information manual provided with this appliance. For assistance 
or additional information consult a qualifi ed installer, service agency or gas supplier.
 LIGHTING INSTRUCTIONS
TO TURN OFF GAS APPLIANCE
THERMOPILE
ELEMENT
THERMO-
ELECTRIQUE
PILOT BURNER
VEILLEUSE
This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1/
NFPA 54, or Natural Gas and Propane Installation Codes, CSA B149.1. (Australia: AS5601-2004, New Zealand: NZS 5261)
FOR UNITS NOT EQUIPPED WITH ELECTRIC SPARK: 
CAUTION: Hot while in operation. Do not touch. Severe Burns may result. Due to high surface temperatures 
keep children, clothing and furniture, gasoline and other liquids having fammable vapors away. Keep burner 
and control compartment clean. See installation and operating instructions accompanying appliance.
STOP! Read the safety information above on this label.
FOR ALL PROPANE UNITS AND 
UNITS EQUIPPED WITH ELECTRIC SPARK BOXES:
1)  Push in gas control knob slightly and turn clockwise                      to  
“OFF”.  Knob  cannot  be  turned  from  “PILOT” to “OFF” unless 
knob is pushed in slightly. Do not force.
Gas Inlet
1 )  Tu r n   o ff   t h e   f l a m e   s w i t c h .
2 )   P u s h   i n   t h e   g a s   c o n t r o l   k n o b   s l i g h t l y   a n d   t u r n   c l o c k w i s e                   t o   “ O F F ” .   D o   n o t   f o r c e .
3 )  Tu r n   o ff   a l l   e l e c t r i c   p o w e r   t o   t h e   a p p l i a n c e   i f   s e r v i c e   i s   t o   b e   p e r f o r m e d .  
       Yo u   m a y   s h u t   o ff   t h e   p i l o t   d u r i n g   p r o l o n g e d   n o n   u s e   p e r i o d s   t o   c o n s e r v e   f u e l .
NORMAL 
OPERATING 
SOUNDS OF 
GAS APPLIANCES
It is possible that you will hear some 
sounds from your gas appliance. This 
is perfectly normal due to the fact that 
there are various gauges and types of 
steel used within your appliance. Listed 
below are some examples. All are 
normal operating sounds and should 
not be considered as defects in your 
appliance.
Blower: 
Regency
®
 gas appliances use high tech 
blowers to push heated air farther into 
the room. It is not unusual for the fan 
to make a "whirring" sound when ON. 
This sound will increase or decrease in 
volume depending on the speed setting 
of your fan speed control.
Burner Tray: 
The burner tray is positioned directly 
under the burner tube(s) and logs and 
is made of a different gauge material 
from the rest of the fi rebox and body. 
Therefore, the varying thicknesses of 
steel will expand and contract at slightly 
different rates which can cause "ticking" 
and "cracking" sounds. You should also 
be aware that as there are temperature 
changes within the unit these sounds will 
likely re-occur. Again, this is normal for 
steel fi reboxes.
Blower Thermodisc: 
When this thermally activated switch 
turns ON it will create a small "clicking" 
sound. This is the switch contacts closing 
and is normal.
Pilot Flame: 
While the pilot fl ame is on it can make a 
very slight "whisper" sound.
Gas Control Valve: 
As the gas control valve turns ON and 
OFF, a dull clicking sound may be audible, 
this is normal operation of a gas regulator 
or valve.
Unit Body/Firebox: 
Different types and thicknesses of steel 
will expand and contract at different 
rates resulting in some "cracking" and 
"ticking" sounds will be heard throughout 
the cycling process.
Copy Of Lighting Plate Instructions 
Adjusting Flame Height
 
Your heater has an adjustable fl ame to tailor the 
look and heat output to your specifi c needs. It 
is adjusted by turning the fl ame adjustment dial 
on the gas control valve.
Turn clockwise to adjust the fl ame higher, coun-
terclockwise 
for a lower 
fl ame.
OPERATING INSTRUCTIONS
AUTOMATIC 
CONVECTION FAN 
OPERATION
The fan operates automatically - turn the knob 
on the pedestal control panel to adjust to the 
desired speed. The fan will turn on as the stove 
comes up to operating temperature. After the 
unit has been turned off and cools to below a 
useful heat output range the fan will shut off 
automatically.