Crown Boiler PN980528R1 产品宣传页

下载
页码 2
Gas-Fired, Direct Vent 
Hot Water Boiler
AVAILABLE FROM:
DIMENSIONS ( in inches )
CROWN Co-axial Horizontal Vent Terminal
CWD SERIES SPECIFICATIONS
LOCATING THE BOILER
• Clearances: Sides 1”, front 3”, rear 1”, top 12”
• 6” clearance to air inlet collar when combustion air is supplied from indoors
• Boiler may be installed directly on a non-carpeted combustible floor
• Relief valve may not be moved from factory location
Important: This boiler requires a special venting system.
Read instructions carefully before installing.
Air inlet collar located on center rear of CWD193 through CWD245
Since 1949, homeowners have depended on us 
for quality, value and service
3633 I Street, P. O. Box 14818
Philadelphia, PA 19134
Phone: (215) 535-8900  Fax: (215) 535-9736
Visit us on the web: www.crownboiler.com
CWD-11/05-(20M)
PN980528R1
Heat Exchanger constructed and tested in accordance 
with ASME Section IV standard.
1. Altitudes above 2,000 ft.–ratings should be reduced at a rate of 4%
for each 1,000 ft. above sea level (U.S.A. only), in Canada, boilers are
certified for altitudes up to 2,000 feet only.
2. Please specify fuel (natural gas or LPG).
3. Specifications and dimensions are subject to change without notice.
*
D.O.E
IBR NET
COLLAR
NO. OF
AGA 
HEATING
WATER
DIAMETER
WIDTH
SHIPPING
Model
SECS.
INPUT
CAPACITY
RATING 
INLET
EXHAUST
A
AFUE
WEIGHT 
BTU/HR
BTU/HR
BTU/HR.
(inches)
(inches)
(inches)
(%)
CWD060 3
60,000
51,000
44,000
4”
3”
16-1/8
85.1
280 
CWD083
4
82,500
71,000
62,000
4”
3”
19-3/4
85.1
315
CWD110
5
110,000
94,000
82,000
4”
3”
23-3/8
85.2
350
CWD138
6
137,500
118,000
103,000
4”
3”
27
85.2
385
CWD165
7
165,000
142,000
123,000
4”
3” or 4”
30-5/8
85.2
420
CWD193
8
192,500
165,000
143,000
4”
3” or 4”
34-1/8
85.2
475
CWD220
9
220,000
189,000
164,000
4”
3” or 4”
32-3/4
85.2
525
CWD245
10
245,000
211,000
183,000
4”
3” or 4”
41-3/8
85.3
580