3. Empty by tilting the container (1) backwards and pour the liquids into a floor 
drain or similar. 
4. Wipe float valve (2), filter (3) and the motor top with a damp cloth before the 
motor top is reinstalled to the container. 
5. Replace the float valve assembly and power head. Secure with the latches. 
 
Emptying GV702-EU 
1.  Drain  hose:  This  mode  has  a  draining  hose  (1)  that  easy  and  comfortable 
drain the container from liquids, Detach the drain hose (1) from the bracket   
(2)  by  pulling  hose  backwards  from  the  cleaner.  Place  the  drain  hose  end 
near  a  floor  drain  and  then  remove  the  plug  at  hose  end.  The  natural 
pressure will then drain the liquids from the container. 
2. Emptying from the container: Pull the lower parts of the latches outwards 
and release the motor top. Remove the motor top. 
3.  The  suction  hose  can be  attached  during  emptying  from  the  container  (3). 
Grasp  with  on  hand  at  the  handle  at  the  lower  part  of  the  container.  To 
avoid  movement  of  the  trolley-place,  one  foot  at  the  base  part  (4)  of  the 
trolley.  Then  tilt  the  container  backwards  and  pour  the  liquids  into  a  floor 
drain or similar. 
4. Wipe float valve (5), filter (6) and the motor top with a damp cloth before the 
motor top is reinstalled to the container. 
5. Replace the motor top. Secure with the latches. 
 
 
 
 
MAINTENANCE 
 
To keep the machine performing well for many years, Please follow the following maintenance procedures. 
 
Always confirm that the machine is unplugged prior to performing any maintenance or repairs. 
1]  Make  sure  that  the  cable  is  not  cut  or  damaged.  (If  it  is,  contact  the  nearest  authorized  service  center  for 
replacement) 
2] Thoroughly clean the tank, do not let it sit for a long time with dust or dirty water. 
3] The cloth dust bag can be washed and must be completely dry before use.   
3] Lubricate casters with a water resistant lubricant every month. 
4] Check machine for loose or missing nuts and bolts and replace as necessary. 
5] Check the filter, and clean it after each use. 
6] The motor is built for maintenance-free operation and does not need any particular service. The carbon brushes 
may need to be replaced due to normal wear and tear caused by using the vacuum cleaner over time, and they 
can be replaced only by an authorized VIPER distributor. 
 
 
ATTENTION 
 
 
                                           
1. To avoid the risk of electrical shock, always insure the four insulation bush (1) are 
installed.
 
 
 
 
 
 
 
 
 
 
 
10 
GV25-EU GV35-EU GV702-EU
 
GV12066(1)2009-01 
1
1
2
4
3
2
3
5
6
1