19
PROBLEM
POSSIBLE CAUSE
SOLUTION
Water.backs.up.into.disposer..
(does.not.drain).
•. The.auger.and.screen.plugged.
•. Auger.not.turning..
•. Plumbing.line.between.disposer.and..
. Waste.Xpress.clogged.
•. Remove.plug.
•. Ensure.that.auger.is.seated.properly.and..
. that.auger.belt.in.place..Check.motor.
•. Remove.clog.
Waste.Xpress,.disposer.and.water.
will.start.when."start".button.is.
pushed.but.shuts.down.when.start.
button.is.released.
•. Insufficient.time.allowed.after.Line..
. Disconnect.switch.on.control.center..
. is.turned.to.the."on".position.
•. 24.V.power.from.control.center..
. (control.circuit).is.low.or.not.present.
•. Mechanical.interlock.on.disposer..
. reversing.contactors.is.defective.
•. Allow.15-20.seconds.prior.to.attempting..
. system.start.up.(at.start.switch).after..
. turning.Line.Disconnect.switch.to.the..
. "on".position.
•. Call.for.service..
•. Call.for.service.
Waste.Xpress.stops.unexpectedly.
•. Discharge.chute.misaligned..
•. Fuse.blown.or.circuit.breaker.tripped..
. at.power.source.
•. 24V.power.from.control.center..
. (control.circuit).is.low.or.not.present.
•. Operation.mode.on.circuit.board.in..
. control.center.is.set.for.10.minute.
. automatic.shutdown.
•. Stop.button.on.control.center.has..
. been.pushed.
•. Line.Disconnect.switch.has.been.
. turned.to."off".position.
•. Reinstall.discharge.chute.to.ensure..
. proper.fit.
•. Replace.fuse.or.reset.circuit.breaker..
•. Call.for.service..
•. Call.for.service..
.
•. Push.start.button.on.control.center..
•. Turn.to."on".position..Wait.15-20.seconds.
. before.attempting.at.starting.system.to.
. allow.control.to.perform."self.test"..
Note: Line Disconnect switch is only 
  intended for use in the event of control  
  center servicing.
Water.exits.Waste.Xpress.
at.front.of.cabinet.
•. Drain.line.has.clog.
•. High.water.level.
•. Clear.drain.
•. Add.second.waste.outlet.drain.connect.from.
. Waste.Xpress.cabinet.to.sewer.connection..
. (recommended.for.trough.applications).
•. Verify.system.has.5.gpm.flow.control.and.
. shut.off.valve.installed..Install.if.missing.
Waste.Xpress.does.not.run,..
but.disposer.and.water.run.
•. Contactor.defective.
•. Waste.Xpress.overload.will.not.reset.
•. Auger.motor.defective.
•. Call.for.service.
•. Call.for.service.
•. Call.for.service.
SYSTEM TROUBLESHOOTING