PROBLEM
POSSIBLE CAUSE
SOLUTION
Auger.runs.in.counterclockwise.
(CCW).direction.
•. Power.to.auger.motor.reversed.
•. Reverse.motor.leads.to.auger.motor.or..
. switch.L1.and.L2.connections.on.Waste..
. Xpress.terminal.block..Auger.must.run.in..
. clockwise.direction.
Unit.does.not.shut.off.with.cover.off.
of.Waste.Xpress.unit.
•. Waste.Xpress.Interlock.not..
. operating.properly.
•. Check.interlock.switch.#3.and.#95..
. connections.on.WX-101A.to.Waste.Xpress.
•. Call.for.service.
Hot.water.spray.is.cold.
•. Incorrectly.plumbed.
•. No.hot.water.
•. Connect.solenoid.on.Waste.Xpress.unit.to..
. hot.water.source.
•. Ensure.hot.water.heater/source..
. is.functioning.
Hot.water.spray.does.not.work.
•. Incorrectly.wired.
•. Check.connections.on.WX-101A.#7.to.
. WX.#18.
Auger.reverses.direction.on..
each.re-start.
•. Waste.Xpress.unit.auger.motor..
. has.been.wired.into.disposer..
. motor.circuit.
•. Re-wire.as.shown.in.instructions.
Waste.Xpress.unit.will.not.start.
•. Incorrect.wiring.
•. Misaligned.Interlock.switch.on.chute.
•. Safety.interlock.switch.is.defective.
•. Check.wiring.
•. Check.chute.for.tight.fit.
•. Call.for.service.
Water.shuts.off.when.unit.shuts.off. •. Improper.dip.switch.setting..
. (circuit.board).
•. Refer.to.Page.16.to.refer.to.dip.switch..
. setting.instructions.
Repetitive."hammering".sound.
coming.from.Waste.Xpress.unit.
while.running.–.no.waste.exiting..
unit.at.discharge.chute.
•. Auger.has.become.plugged.–.system..
. has.either.been."batch.fed".or.auger.
. drive.system.has.failed..Waste.buildup.
. causing.auger.to.malfunction.–.not..
. engaging.with.auger.drive.correctly.
•. Shut.system.down.and.clean.unit...
. Determine.cause.of.plug.
Waste.line.clogs.between.disposer.
and.Waste.Xpress.unit.
•. System.is.being."batch.fed.".
.
•. System.is.being.shut.down..
. prematurely.-.not.being.allowed.to..
. properly.clear.itself.of.waste.
•. Auger.and.screen.not.being.cleaned..
. properly..Waste.build.up.has.hardened.
. and.created.a.clog.over.time.
•. Auger.is.running.in.wrong.rotation.
•. Lack.of.cold.water.flowing..
. through.system.
•. Waste.mix.has.a.high.fiberous..
. content.(stringy.food.waste..
. and/or.cardboard).
•. Feed.waste.at.a.moderate.and.even.rate.–..
. do.not.attempt.to.process.high.volume.all..
. at.one.time.
•. Allow.system.to.run.3-5.minutes.before..
. shutting.the.sytem.down.to.clear.itself..
•. Disassemble.and.clean.the.Waste.Xpress..
. unit.a.minimum.of.once.per.day..
•. Call.for.service.
•. Increase.water.flow.to.5.gpm..
•. Card.board.cannot.be.processed..Fiberous..
. food.waste.should.be.balanced.into.the..
. waste.mix.with.other.food.waste.products
WASTE XPRESS TROUBLESHOOTING