Prepare Site
3
4 Prepare Site
Your U-Line product has been designed for either free-standing or 
built-in installation. When built-in, your unit does not require 
additional air space for top, sides or rear. However, the front grille 
must NOT be obstructed and clearance is required for an 
electrical connection in the rear.
WARNING
Unit can NOT be installed behind a closed cabinet door.
WARNING
SHOCK HAZARD — Electrical Grounding Required. 
• Never remove the round grounding prong from the 
plug and never use a two-prong grounding adapter.
• Never use an extension cord to connect power to the 
unit.
IMPORTANT
IMPORTANT
Electrical installation must observe all state and local 
codes. This unit requires connection to a grounded (three-
prong), polarized receptacle that has been placed by a 
qualified electrician.
The unit requires a grounded and polarized 115 VAC, 60 Hz, 15A 
power supply (normal household current). An individual, properly 
grounded branch circuit or circuit breaker is recommended. GFCI 
(ground fault circuit interrupter) is usually not required for fixed 
location appliances and is not recommended for your unit because 
a GFCI could be prone to nuisance tripping. However, be sure to 
consult your local codes.
Cut-Out Dimensions
1175, 1075 & 75F Series
Follow the cut-out drawing. The 24-1/4" width allows 1/4" for ease 
in installation and removal of the unit. 24" is the cabinet depth in 
most installations. 
1115 Series
Follow the cut-out drawing The 15-3/16" width allows 1/4" for 
ease in installation and removal of the unit. 24" is the cabinet depth 
in most installations. 
29 Series
Follow the cut-out drawing. The 21-1/16" width allows 1/4" for 
ease in installation and removal of the unit. 24" is the counter 
depth in most installations. The unit is 23" deep including the door. 
ADA24 Series
Follow the cut-out drawing The 24 1/4" width allows 1/4" for ease 
in installation and removal of the unit. 24" is the cabinet depth in 
most installations. 
24”
1-1/2"
15-1/4"
7"
34-1/8"
to
35"
24"
Minimum
21-1/16"
Typical
Counter
Height
34-1/4"
to
35-1/8"
Cut-Out
Height
28-5/8"
to
28-7/8"
Filler Panel (Not Provided by U-Line) –
May Be Added Above or Below Unit
to Enclose for a Built-In Look 
7"
1-1/2"
4"
7"
24"
24-1/4"
34-1/4"
to
35-1/8"
4"
7"
24"
24-1/4"
32”