Hoshizaki KM-901MAH 用户手册

下载
页码 87
4
2. Sequence Flow Chart
a) "E" Control Board: Auxiliary Code T-0, U-0
4. Pump-Out Cycle
• Factory set for every 
0th cycle (S4 dip 
switch 5 & 6)
• Pump motor stops 
for 
 
sec., then 
reverses for 
0/
sec. (S4 dip switch 
3 & 4)
F/S
 Check
Components Energized when the Control Switch is in the "WASH" Position
The "WASH" position on the control switch is used when cleaning and sanitizing the unit. When in the "WASH" position, 
power is supplied to the pump motor. With the cleaning valve closed, the cleaner and sanitizer flow over the outside of 
the evaporator plate assembly. With the cleaning valve open, the cleaner and sanitizer flow over both the outside and the 
inside of the evaporator plate assembly. 
Note: Close the cleaning valve after cleaning and sanitizing are complete, otherwise the unit will not restart when the 
 
         
          control switch is placed in the "ICE" position.
Legend:
Comp
–compressor
FM
–fan motor
FMR
–fan motor-remote
F/S
–float switch
HGV
–hot gas valve
 
LLV
–liquid line valve
TBC
–thermostatic bin control
PM
–pump motor
WV
–inlet water valve
"E" Control Board Sequence Flow Chart
1. 1-Minute Fill 
Cycle
2. Harvest Cycle
3. Freeze Cycle
Cycle Steps
WV
 energized
F/S
 open
F/S
 closed
WV
 continues
Comp
 energized
HGV
 energized
FMR
 energized
Thermistor temperature 
reaches 48
°F (9°C) 
(3.9 kΩ or less) Harves
timer s
tarts
F/S
 open
Comp
 continues
FMR
 continues
PM
 energized
FM
 energized
LLV 
energized
HGV
 de-energized
WV
 de-energized
F/S
 closed
F/S
 Check
• WV time: 6 min. or the length of harvest, 
whichever is shorter.
• Maximum harvest time: 
0 min.
Thermistor in control
 to 3-min. timer in control 
(S4 dip switch 
 & 
)
• Minimum freeze time: 5 min.
• Maximum freeze time: freeze timer setting 
(S4 dip switch 9 & 
0
5-min. timer 
in control
F/S
 in control
Initial startup 
begins here 
after 5
 sec. 
delay
If 
F/S
 is open, compressor stops and cycle returns to 
-Minute Fill Cycle
1. Bin Full
    
Unit shuts down   
 
     within 
0 sec. 
 
   
 
     after ice contacts 
 
     thermostatic bulb.
Shutdown 
and Restart
TBC Operation
Ice contacts 
thermostatic bulb
2. Icemaker Off
     All components 
   
  
     de-energized.
3. Ice Level Lowered
     Ice level lowered. No ice 
 
     touching thermostatic  
 
     bulb. Icemaker starts at
     "
-Minute Fill Cycle."
TBC
 closed
TBC
 open
All components 
de-energized
To 
 above
Comp
 continues
FMR
 continues
HGV
 energized
PM
 de-energizes for 
 
sec.,  
 
      then reverses for 
0/
0 sec. 
  
FM
 de-energized
LLV 
de-energized
F/S
 open or freeze 
timer expires
KM-901MAH, KM-901MWH, KM-901MRH/3