Hoshizaki KM-901MAH 用户手册

下载
页码 87
78
Fig. 4
Adjustment Screw
CW – Higher
CCW – Lower
Top View
8) Check for water leaks.
9) Replace the panels in their correct positions.
0) Turn on the power supply.
J. Adjustment of Water Regulating Valve (water-cooled model)
The water regulating valve (also called "water regulator") is factory set, and generally no 
adjustment is required. However, when necessary, adjust the water regulator using the 
following procedures.
) Prepare a thermometer to check the condenser drain temperature. Attach a pressure 
gauge to the high-side line of the system.
) Five minutes after a freeze cycle starts, 
confirm that the thermometer reads 04°F 
to 5°F (40°C to 46°C). If it does not, 
rotate the adjustment screw by using a flat 
blade screwdriver until the temperature 
is in the proper range. See Fig. 4. Next, 
check that the reference pressure is in the 
range indicated in the Head Pressure table 
in the Performance Data section. If it is not 
in the proper range, verify the refrigerant 
charge.
3) Check that the condenser drain temperature is stable.
K. Removal and Replacement of Headmaster (Condensing Pressure 
Regulator - C.P.R.) (remote air-cooled model)
CAUTION
. Always install a new drier every time the sealed refrigeration system is 
opened. 
. Do not replace the drier until after all other repair or replacement has been 
made. Install the new drier with the arrow on the drier in the direction of the 
refrigerant flow.
3. When brazing, protect the headmaster and drier by using wet cloths to 
prevent the headmaster and drier from overheating. Do not allow the 
headmaster or drier to exceed 50°F (°C).
) Turn off the power supply.
) Remove the panels from the remote condenser unit.
3) Recover the refrigerant and store it in an approved container.
4) Before heating, break off the stub on the dome to release the dome charge.
5) Disconnect the headmaster.
6) Place the new headmaster in position.
7) Remove the drier, then place the new drier in position.