Fujitsu TX200 S3 用户手册
*1. By applying Internal HDD Unit Bay Conversion kit (PG-BC103), 5 inch bay x 2 can be converted
to 3.5 inch bay x 2.
When Internal HDD Unit Bay Conversion kit (PG-BC103) is applied, Internal Backup Device
cannot be mounted on 5inch Bay.
*2. By applying Power Supply Conversion kit (PGBRSU104), non-redundant structure (Power Supply x1,
FAN x2) can be converted to redundant structure (Power Supply x2, FAN x6).
*3. Frequency will be changed by the spec of PCI card and number of cards mounted.
*Components installed as standard configuration marked in grey.
PCI Slot
* No AFT/ALB Support
* [n] : Installation Priority
* # : standard
* # : standard
* - : cannot be installed
*1.Frequency will be changed by the spec of PCI card and number of cards mounted.
-
Eth. Ctrl 1x1Gbit PCI-E
1000BASE-SX
1000BASE-SX
PG-288
PCI Express
(x4)
(x4)
-
-
[1]
[2]
-
[2]
[2]
2
2
PCI Express Card
-
PCI Express Card
PCI Express Card
-
PCI Express Card
-
2
2
[3]
Internal/External SCSI
Controller
Controller
Fibre Channel Controller
PG-FC202 /
PGBFC202
PGBFC202
PCI Express
(x4)
(x4)
-
-
-
[1]
[2]
[2]
[1]
-
-
SCSI Ctrl U160
PG-1281 /
PGB1281
PGB1281
PCI/64bit
-
[2]
[1]
-
-
-
RAID Ctrl 2-Channel 128MB
w/ BBU
w/ BBU
PG-142E3 /
PGB142E3
PGB142E3
PCI/64bit
-
Eth. Ctrl 2x1Gbit PCI-X
1000-BASE-T
1000-BASE-T
PG-1863
PCI-X/64bit
-
[1]
[2]
-
-
-
[3]
[1]
[2]
-
-
[3]
-
-
Eth. Ctrl 1000-BASE-T Cu
PG-1892 /
PGB1892
PGB1892
PCI-X/64bit
-
-
[3]
Internal array
External array
2
[3]
2
[3]
2
Standard, Internal array
1
PG-140G /
PGB140G
PGB140G
PCI-X/64bit
-
[1]
-
-
-
Internal array
SAS RAID Ctrl
PG-140F /
PGB140F
PGB140F
PCI-X/64bit
-
SAS Controller
(8ports)
(8ports)
-
PCI-X/64bit
#
-
Remarks
10
1
2
3
4
5
PCI-X
PCI Express
PCI
x8
lane
x4
lane
32bit/
33MHz
Full Height
Mountable Cards
Bus
64bit/
100MHz
64bit/
100MHz *1
3.3V
Mount
Priority
Eth. Ctrl 2x1Gbit PCI-E
1000-BASE-T
1000-BASE-T
PG-2861 /
PGB2861
PGB2861
PCI Express
(x4)
(x4)
-
-
-
[1]
[1]
-
[1]
[2]
-
[1]
[2]
Max No.
of Mount
of Mount
3
2
2
1
1
1
2
2
-
x8 socket
5.0V
-
-
-
-
-
-
-
SAS RAID Ctrl
Eth. Ctrl 1x1Gbit PCI-E
1000-BASE-T
1000-BASE-T
PG-289 /
PGB289
PGB289
PCI Express
(x1)
(x1)
Eth. Ctrl 1x1Gbit PCI
1000-BASE-T
1000-BASE-T
PG-1853 /
PGB1853
PGB1853
PCI/32bit
Eth. Ctrl 1000-BASE-SX
Fibre LC
Fibre LC
PG-1882
PCI-X/64bit
-
-
-
[1]
Configuration Diagram
Power Supply Unit
PCI Slots
5 inch Bay 3
5 inch Bay 2
5 inch Bay 1
CD-ROM Drive / FDD
Mountable I/O Options
PRIMERGY TX200 S3
Memory
DIMM Slot 3B
DIMM Slot 2B
DIMM Slot 1B
DIMM Slot 3A
DIMM Slot 2A
DIMM Slot 2B
DIMM Slot 1B
DIMM Slot 3A
DIMM Slot 2A
Power Supply Unit
DIMM Slot 1A
CPU
Xeon®
X5355 (2.66GHz)/
E5310 (1.60GHz)/
5160 (3GHz)/
5130 (2GHz)/
5110 (1.60GHz)
X5355 (2.66GHz)/
E5310 (1.60GHz)/
5160 (3GHz)/
5130 (2GHz)/
5110 (1.60GHz)
3.5 inch HDD Bay 6
(hot plug)
(hot plug)
3.5 inch HDD Bay 5
(hot plug)
(hot plug)
3.5 inch HDD Bay 4
(hot plug)
(hot plug)
3.5 inch HDD Bay 3
(hot plug)
(hot plug)
3.5 inch HDD Bay 2
(hot plug)
(hot plug)
3.5 inch HDD Bay 1
(hot plug)
(hot plug)
*2
*1
Bay 6
SAS
Bay 5
SAS
Bay 4
SAS
Bay 3
SAS
Bay 2
SAS
Bay 1
SAS
Hard Disk 3.5inch Bay (hot plug)
Standard Drive Cage ( HDD x 6ports )
Standard Drive Cage ( HDD x 6ports )
Bay 7
SAS
Bay 8
SAS
When Internal HDD Unit Bay Conversion kit (PG-
BC103) is applied. ( HDD x 2ports )
Internal Backup Device cannot be mounted
because 5inch Bay x 2 is used by HDDs.
BC103) is applied. ( HDD x 2ports )
Internal Backup Device cannot be mounted
because 5inch Bay x 2 is used by HDDs.
PCI5 PCI 32bit/33MHz
PCI4 PCI Express (x4)
PCI2 PCI-X 64bit/100MHz *3
PCI3 PCI Express (x8)
PCI1 PCI-X 64bit/100MHz *3
PCI10 PCI-X 64bit/100MHz
High
Low
Xeon®
X5355 (2.66GHz)/
E5310 (1.60GHz)/
5160 (3GHz)/
5130 (2GHz)/
5110 (1.60GHz)
X5355 (2.66GHz)/
E5310 (1.60GHz)/
5160 (3GHz)/
5130 (2GHz)/
5110 (1.60GHz)
High
Low