Marantz PD4201 用户手册
PDxx01
RS-232C Control Specification Page: 16 / 49
Document Version [1.0]
Company Restricted
5-19.
TREBLE Gain Data
Function
The external control equipment changes the TREBLE gain data of the plasma monitor.
Transmission Data
The external control equipment changes the TREBLE gain data of the plasma monitor.
Transmission Data
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA0 CKS
DATA00: USER PICTURE Gain Flag
05H
DATA01: TREBLE Gain Flag
04H
DATA02: TREBLE Gain
F3H: -13
:
FFH:
-01
00H:
0
01H:
+01
:
0DH:
+13
ACK
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS
DATA00: USER PICTURE Gain Flag
05H
DATA01: TREBLE Gain Flag
04H
5-20.
BALANCE Gain Data
Function
The external control equipment changes the BALANCE gain data of the plasma monitor.
Transmission Data
The external control equipment changes the BALANCE gain data of the plasma monitor.
Transmission Data
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS
DATA00: USER PICTURE Gain Flag
05H
DATA01: BALANCE Gain Flag
02H
DATA02: BALANCE Gain
EAH: -22
:
FFH:
-01
00H:
0
01H:
+01
:
16H:
+22
ACK
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS
DATA00: USER PICTURE Gain Flag
05H
DATA01: BALANCE Gain Flag
02H