5-73.
POWER ON MODE (VOLUME)
Function
Power-on modes (Volume) are set up.
Transmission Data
Power-on modes (Volume) are set up.
Transmission Data
DFH 80H 60H 0FH 01H DATA00 CKS
DATA00: Power ON mode (VOLUME)
A0H:
LAST
00H:
volume0
:
2A H: volume42
ACK
7FH 60H 80H 0FH 00H CKS
5-74.
74. SUB PICTURE RATE set
Function
Sub screen rate of PIP are set up.
Transmission Data
Sub screen rate of PIP are set up.
Transmission Data
DFH 80H 60H DAH 02H DATA00 DATA01 CKS
DATA00: Sub screen rate Gain flag
01H
DATA01: Sub screen rate Gain
00H: 20%
01H: 30%
01H: 30%
02H:
40%
03H:
50%
04H: 60%
05H:
70%
06H:
80%
07H: 90%
08H:
100%
DATA02:
FADE
00H:
NORMAL
01H: FADE
ACK
7FH 60H 80H DAH 01H DATA00 CKS
DATA00: Sub screen rate Gain flag
01H