Enterasys csx400 用户指南
![Enterasys](https://files.manualsbrain.com/attachments/0d61cd0d9a60e36f1a6c1364af6a0a9788bcf75b/common/fit/150/50/0c43aa9c6913c8f0c68912f62e6506afc95280a8d9a1fc71e52e7f54646e/brand_logo.jpeg)
Configuration: Call Backup
Local Management User’s Guide
2-41
Configure the D Channel
Use the following command in Network Tools to set the switch type:
setswitchtype [WANPORTNUM] [SWITCHTYPE]
WANPORTNUM —
If the HSIM or CyberSWITCH occupies WAN port number one, use 1, if it
occupies port number two, use 2 as the WANPORTNUM.
SWITCHTYPE —
Choose between the types of ISDN BRI switches. The choices are NI1 (default
for BRI), DMS100 (BRI/PRI), ATT5 ESS (BRI/PRI, default for PRI), ATT-4ESS (PRI) and
NET3 (BRI).
NET3 (BRI).
Set Phone Numbers and SPIDs for the Port
The following Network Tools command is used to set the phone numbers and the SPIDs (if
applicable):
applicable):
setisdnbri [WANPORTNUM] [LDN1][SPID1] [LDN2] [SPID2]
LDN1 —
The first Local Directory Number. Likewise, LDN2 is the second Local Directory
Number.
SPID1 —
The first Service Profile Identifier. Likewise, SPID2 is the second Service Profile
Identifier.
SPID format: [XXXYYYZZZZ] [01] [01]
Where XXX represents the area code, YYY represents the prefix, and ZZZZ represents the local
number. [01] [01] is the fixed suffix. This is the proposed generic SPID format.
number. [01] [01] is the fixed suffix. This is the proposed generic SPID format.
Example 1: For the first WAN port to be configured for ISDN, issue the command:
setisdnbri 1 5551000 0555100001 5553000 0555300001
For the second WAN port to be configured, issue the command:
setisdnbri 2 5551000 0555100001 5553000 0555300001
The command also allows for skipping or clearing any entry by using the key letters S (or s) to skip
the field, and C (or c) to clear the field.
the field, and C (or c) to clear the field.
Example 2: To skip LDN1 and SPID1, change LDN2, and clear SPID 2, issue the following
command:
command:
setisdnbri 2 s s 0555600001 c