Configuration: Call Backup
Local Management User’s Guide
2-41
Configure the D Channel 
Use the following command in Network Tools to set the switch type:
setswitchtype [WANPORTNUM] [SWITCHTYPE]
WANPORTNUM —
If the HSIM or CyberSWITCH occupies WAN port number one, use 1, if it 
occupies port number two, use 2 as the WANPORTNUM.
SWITCHTYPE —
Choose between the types of ISDN BRI switches. The choices are NI1 (default 
for BRI), DMS100 (BRI/PRI), ATT5 ESS (BRI/PRI, default for PRI), ATT-4ESS (PRI) and 
NET3 (BRI).
Set Phone Numbers and SPIDs for the Port 
The following Network Tools command is used to set the phone numbers and the SPIDs (if 
applicable):
setisdnbri [WANPORTNUM] [LDN1][SPID1] [LDN2] [SPID2] 
LDN1 —
The first Local Directory Number. Likewise, LDN2 is the second Local Directory 
Number.
SPID1 —
The first Service Profile Identifier. Likewise, SPID2 is the second Service Profile 
Identifier. 
SPID format: [XXXYYYZZZZ] [01] [01]
Where XXX represents the area code, YYY represents the prefix, and ZZZZ represents the local 
number. [01] [01] is the fixed suffix. This is the proposed generic SPID format.
Example 1: For the first WAN port to be configured for ISDN, issue the command:
setisdnbri 1 5551000 0555100001 5553000 0555300001
For the second WAN port to be configured, issue the command:
setisdnbri 2 5551000 0555100001 5553000 0555300001
The command also allows for skipping or clearing any entry by using the key letters S (or s) to skip 
the field, and C (or c) to clear the field.
Example 2: To skip LDN1 and SPID1, change LDN2, and clear SPID 2, issue the following 
command:
setisdnbri 2 s s 0555600001 c