WPIM-SY Physical Configuration Fields
The configuration fields specific to the WPIM-SY shown in
Sync Port Type —
Displays the Synchronous port electrical interface type. The selections toggle
between V.35, X.21, None, RS232, and RS422. This field always displays a Synchronous Port
Type, even if the Synchronous Port is not the active WAN port. The default setting for this field is
V.35.
Type, even if the Synchronous Port is not the active WAN port. The default setting for this field is
V.35.
Force CTS True —
Displays the source of the Clear To Send (CTS) signal. The CTS signal is an
input to the WPIM-SY. The WPIM-SY can either use or ignore the CTS signal. You can toggle the
selections between Yes and No. The Yes (On) setting indicates that the WPIM-SY ignores the CTS
signal from an external DCE (Data Communications Equipment) and forces the signal high. The
No (Off) setting indicates that the CTS signal is received from an external DCE. The default
setting is No.
selections between Yes and No. The Yes (On) setting indicates that the WPIM-SY ignores the CTS
signal from an external DCE (Data Communications Equipment) and forces the signal high. The
No (Off) setting indicates that the CTS signal is received from an external DCE. The default
setting is No.
Force DSR True —
Displays the source of the Data Set Ready (DSR) signal. You can toggle the
selections between Yes and No. The Yes (On) setting indicates that the DSR is internally “Forced
True” . The No (Off) setting indicates that the DSR signal is received from an external DCE. The
default setting is No.
True” . The No (Off) setting indicates that the DSR signal is received from an external DCE. The
default setting is No.
Force RTS True —
Displays the setting of the Ready To Send (RTS) signal. RTS Enable places
the modem in the originate mode so it can begin to send. The default setting is Enable. The other
choice is Disable. Used for sync modem backup. See
choice is Disable. Used for sync modem backup. See
.
Force DTR True —
Displays the setting of the Data Terminal Ready (DTR) signal. DTR Enable
indicates that the DTE is powered on and ready to communicate. The default setting is Enable. The
other choice is Disable. Used for sync modem backup. See
other choice is Disable. Used for sync modem backup. See
Sync Clock Source —
Displays the clock source as External, Split, or Internal. The default
setting is External. The Internal and Split settings are for Cabletron testing purposes only. Always
set this field to External.
set this field to External.
Sync Tx Clock Speed —
Cabletron testing purposes only. Displays 64000 (Kbps) upon startup.
Sync Rx Clock Speed —
This field displays the manually inputted receive clock speed. The
default setting for this field is 64000 (Kbps). The information for this field is normally supplied by
the Service Provider.
the Service Provider.