To configure user event buttons:
1.
In the tree, select System Devices > Operator Client Event Buttons > Event Button 
Pressed
The corresponding Event Configuration Table is displayed.
2.
Select a user event button to configure its behavior. 
3.
In the Trigger Alarm - Schedule column, click a cell and select the appropriate schedule.
The schedule determines when the alarm that is supposed to notify the user is triggered. 
4.
In the Log - Schedule column, click a cell and select the appropriate schedule. 
The schedule determines when the event is logged. 
Selecting Never makes the user event button unavailable in the Operator Client of all 
user groups that have the user event button permission. 
During the selected schedule, each Event Button Pressed event is displayed in the Event 
List of each user.
5.
In the Script - Script column, click a cell and select an appropriate Command Script.
6.
In the Script - Schedule column, click a cell and select the appropriate schedule.
The schedule determines when the Command Script is executed. 
7.
In the Minimum Event Time column, click a cell and type the number of milliseconds as 
the minimum time period that the event must last to be a single event.
11.8
Creating a Compound Event
Main window > 
 Events > 
changes and their objects. Objects can be for example schedules or devices. You can combine 
both the state changes and their objects with the Boolean expressions AND and OR. 
Example: You combine the connection states of an IP camera and a decoder. The Compound 
Event shall only occur when both the devices loose their connection. In this case you use the 
AND operator for the two objects (the IP camera and the decoder) and for the two connection 
states Video Signal Lost and Disconnected.