Cisco me-4924-10ge 安装指导

下载
页码 74
   
4-3
Cisco ME 4924-10GE Ethernet Switch Hardware Installation Guide
OL-10071-01
Chapter 4      Troubleshooting
    Troubleshooting the Hardware Components
Troubleshooting the Hardware Components
This chapter describes how to troubleshoot the Cisco ME 4924-10GE-10GE switch hardware and 
contains these sections:
If your system has problems starting up, use the information in this chapter to help isolate the cause. 
Problems with the initial startup are often caused by poor or improper connections. Although 
temperature conditions above the maximum acceptable level rarely occur at initial startup, 
environmental monitoring functions are included because they also monitor DC-line voltages. 
Note
For configuration questions or problems, refer to the software configuration guide or the command 
reference publication to configure or enable the interfaces. 
Unreadable characters on the 
management console
Incorrect baud rate.
Reset the emulation software to 
9600 baud.
Amber STATUS LED
POST error detected. It may or may 
not be a fatal error.
Contact Cisco Systems.
The switch port is placed in 
error-disabled state after SFP is 
inserted
Bad or non-Cisco-approved SFP.
Remove the SFP module from 
the switch, and replace it with a 
Cisco-approved module. Use the 
errdisable recovery cause 
gbic-invalid 
global 
configuration command to 
verify the port status, and enter a 
time interval to recover from the 
error-disable state.
Refer to the switch command 
reference guide for information 
on the errdisable recovery 
command.
Switch does not recognize the 
SFP module
The SFP module might be installed 
upside down.
The SFP module does not snap into 
the port.
Verify that the SFP module is 
not installed upside down.
Remove the SFP module. 
Inspect for physical damage to 
the connector, the module, and 
the port.
Replace the SFP module with a 
known good SFP module.
Table 4-1
Common Problems and Solutions (continued)
Symptom
Possible Cause
Resolution