Alcatel-Lucent 6850-48 网络指南

下载
页码 1162
802.1Q Specifications
Configuring 802.1Q
page 21-2
OmniSwitch AOS Release 6 Network Configuration Guide
September 2009
802.1Q Specifications
Note. Up to 4093 VLANs can be assigned to a tagged port or link aggregation group. However, each 
assignment counts as a single VLAN port association. Once the maximum number of VLAN port associa-
tions is reached, no more VLANs can be assigned to ports. For more information, see the chapter titled 
 
802.1Q Defaults Table
The following table shows the default settings of the configurable 802.1Q parameters.
802.1Q Defaults
IEEE Specification
Draft Standard P802.1Q/D11 IEEE Standards for 
Local And Metropolitan Area Network: Virtual 
Bridged Local Area Networks, July 30, 1998
Platforms Supported
OmniSwitch 6400, 6800, 6850, 6855, and 9000
Maximum Tagged VLANs per Port
4093
Maximum Untagged VLANs per Port
One untagged VLAN per port.
Maximum VLAN Port Associations (VPA) 
per switch
32768
Maximum 802.1Q VLAN port associations 
per switch
2500 (OmniSwitch 6400)
Force Tag Internal
Not configurable on the OmniSwitch 6400, 6800, 
6850, 6855, and 9000
Parameter Description
Command
Default Value/Comments
What type of frames accepted
Both tagged and untagged 
frames are accepted