ip bfd-std receive
Configures the global receive time interval for BFD control packets. This command specifies the mini-
mum amount of time BFD waits to receive control packets before determining there is a problem.
ip bfd-std receive receive-interval
Syntax Definitions
receive-interval
The receive time interval, in milliseconds. The valid range is 100–999.
Defaults
Platforms Supported
OmniSwitch 6400, 6850, 6855, 9000, 9000E
Usage Guidelines
• The minimum receive time interval is also configurable at the BFD interface level. Note that configur-
ing the global value with the ip bfd-std receive command does not override the value set for the inter-
face using the ip bfd-std interface receive command.
• The global receive time interval serves as the default interval value for a BFD interface. The default 
interval value is overridden when a specific value is configured for the interface. 
Examples
-> ip bfd-std receive 500
Release History
Release 6.3.4; command was introduced.
Related Commands
MIB Objects
alaBfdGlobalRxInterval
parameter
default
receive-interval
100 milliseconds